Plan Review Notes For Permit 13040020 |
Permit Number |
13040020 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2013-04-10 13:41:11 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) FBCR 4101.6.3 STATES THAT WATER VELOCITY IN POOL | | PIPING SHALL NOT EXCEED 8 FEET PER SECOND IN SUCTION | | PIPING. ANSI/APSP 7 2006 SECTION 4.4 STATES THAT WATER | | VELOCITY IN FIELD FABRICATED PIPING IS BASED ON THE | | MAXIMUM SYSTEM FLOW RATE. THE PUMP PERFORMANCE CURVE | | FOR THE PENTAIR INTELLIFLO VS+SVRS 3050 VARIABLE SPEED | | PUMP HAS A MAXIMUM FLO RATE OF 145 G.P.M. WITH A 50' | | TDH. THE WATER VELOCITY IN 2-1/2 " PIPE AT THE MAXIMUM | | FLOW RATE OF 145 GPM IS 9.48 FT PER SECOND WHICH | | EXCEEDS THE 8 FEET PER SECOND ALLOWED BY CODE. PLEASE | | CORRECT. | | | | 2) PLEASE SPECIFY THE PROPOSED PUMP SIZE AND MODEL ON | | THE POOL PLANS. CITY AMENDMENTS 107.2.1 | | THIS REVIEWED WAS BASED ON THE POOL PUMP THAT WAS | | INDICATED ON THE PENTAIR TDH CALCULATOR PAGE THAT WAS | | STAPLED TO THE PLANS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|