Date Text
2013-04-10 13:41:112010 FBC
  
 DENIED BY BUILDING
  
 1) FBCR 4101.6.3 STATES THAT WATER VELOCITY IN POOL
 PIPING SHALL NOT EXCEED 8 FEET PER SECOND IN SUCTION
 PIPING. ANSI/APSP 7 2006 SECTION 4.4 STATES THAT WATER
 VELOCITY IN FIELD FABRICATED PIPING IS BASED ON THE
 MAXIMUM SYSTEM FLOW RATE. THE PUMP PERFORMANCE CURVE
 FOR THE PENTAIR INTELLIFLO VS+SVRS 3050 VARIABLE SPEED
 PUMP HAS A MAXIMUM FLO RATE OF 145 G.P.M. WITH A 50'
 TDH. THE WATER VELOCITY IN 2-1/2 " PIPE AT THE MAXIMUM
 FLOW RATE OF 145 GPM IS 9.48 FT PER SECOND WHICH
 EXCEEDS THE 8 FEET PER SECOND ALLOWED BY CODE. PLEASE
 CORRECT.
  
 2) PLEASE SPECIFY THE PROPOSED PUMP SIZE AND MODEL ON
 THE POOL PLANS. CITY AMENDMENTS 107.2.1
 THIS REVIEWED WAS BASED ON THE POOL PUMP THAT WAS
 INDICATED ON THE PENTAIR TDH CALCULATOR PAGE THAT WAS
 STAPLED TO THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]