Plan Review Notes
Plan Review Notes For Permit 13040011
Permit Number 13040011
Review Stop B
Sequence Number 2
Notes
Date Text
2013-06-03 15:59:27BUILDING PLAN REVIEW
 PERMIT: 13040011
 ADD: 1002 GREEN PINE BLVD # B1
 CONT: H LAYTON MAINGUY GC
 TEL: (954)249-8500
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: 6/03/ 2013
 ACTION: PROVISO
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) THE PRODUCT APPROVAL SUBMITTED FOR THE HORIZONTAL
 SLIDERS DOES NOT INCLUDE MULLIONS WINDOW TYPE D
 INDICATES THERE ARE TWO ADJOINING WINDOWS THAT WILL
 REQUIRE EITHER A MULLION OR A STRUCTURAL FRAMING MEMBER
 TO TRANSFER THE WINDOW LOADS IN TO THE EXTERIOR WALL
 SYSTEM, PART OF THE MWFRS, PLEASE SHOW COMPLIANCE WITH:
 MULLIONS OR MULLED FENESTRATION ASSEMBLIES SHALL BE
 TESTED BY AN APPROVED TESTING LABORATORY IN ACCORDANCE
 WITH EITHER AAMA 450, ASTM E 330, OR TAS 202 (HVHZ
 SHALL COMPLY WITH TAS 202), OR SHALL BE ENGINEERED IN
 ACCORDANCE WITH AAMA 450 USING ACCEPTED ENGINEERING
 PRACTICE. MULLIONS TESTED AS STAND-ALONE UNITS OR
 QUALIFIED BY ENGINEERING SHALL USE PERFORMANCE CRITERIA
 CITED IN SECTIONS 1715.5.5.2, 1715.5.5.3 AND
 1715.5.5.4. MULLIONS QUALIFIED BY AN ACTUAL TEST OF AN
 ENTIRE ASSEMBLY SHALL COMPLY WITH SECTION 1715.5.5.4,
 EXCEPT THAT MULLIONS IN ASSEMBLIES REQUIRING A
 DEFLECTION LIMITATION, AS DEFINED IN AAMA/WDMA/CSA
 101/I.S.2/A440, SHALL MEET 1715.5.5.2 AND 1715.5.5.3.
 PRODUCTS NOT INCLUDED WITHIN THE SCOPE OF SECTION
 1715.5.5.1 SHALL COMPLY WITH SECTIONS 1715.5.5.3 AND
 1715.5.5.4.
 1715.5.5.2 LOAD TRANSFER.
 1715.5.5.3 DEFLECTION.
 1715.5.5.4 STRUCTURAL SAFETY FACTOR.
 1715.5.5.4 STRUCTURAL SAFETY FACTOR.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved