Date |
Text |
2013-03-25 11:28:24 | RESIDENTIAL (R3) ALTERATIONS BUILDING REVIEW COMMENTS. |
| CODE: 2010 FBC. |
| |
| 1- ACCORDING TO SEC. R301.2.1.4.3 OF 2010 |
| FBC-RESIDENTIAL THIS BUILDING IS LOCATED ON EXPOSURE |
| "C" NOT "B". ENGINEER OF RECORD TO REVISE DESIGN |
| CRITERIA AND DESIGN PRESSURES ON SHEET S-1. |
| |
| 2- BRING PLANS TO PALM BEACH COUNTY BUILDING (2300 N. |
| JOG RD) TO VERIFY IF IMPACT FEES ARE DUE FOR THE |
| PROPOSED STUDIO. BRING BACK STAMPED PLANS AND COPY OF |
| PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY |
| IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT |
| CODE. |
| |
| 3- SPECIFY SIZE OF MIDDLE BEDROOM WINDOWS TO VERIFY |
| COMPLIANCE WITH EGRESS SEC. R310. |
| |
| 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| DCA RULE 9N-3 FOR: |
| A) WINDOW MULLIONS. NOA 10-0819.05 SUBMITTED WAS |
| SUPERSEDED BY MIAMI-DADE. VISIT THE MIAMI-DADE WEBSITE |
| AND DOWNLOAD CURRENT NOA. |
| B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON SHEET |
| S-1. PROVIDE ONLY THE COVER PAGE AND PAGE SHOWING THE |
| CONNECTOR. |
| C) INSWING ENTRY DOOR AS SHOWN ON PLANS. |
| |
| 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC. |
| |
| 6- REVISE ENERGY CALCULATIONS. SEC. 107.2.1 CITY |
| AMENDMENTS TO FBC. |
| A) PROVIDE COMPLETE SPECIFICATIONS AND DETAILS ON PLANS |
| TO SHOW COMPLYING WITH ALL THE CREDITS TAKEN IN ITEM |
| #15 (CF, CV) AS REQUIRED BY SEC. 405.6 OF 2010 |
| FBC-ENERGY CONSERVATION. |
| B) REVISE DOOR TYPE SHOWN ON SHEET 3 OF 5. WHERE IS THE |
| WOOD DOOR. SEE PRODUCT APPROVALS SUBMITTED. |
| C) OVERHANG DEPTH AND SEPARATION DIMENSIONS SHOWN ON |
| SHEET 3 OF 5 FOR THE WINDOWS IS INCORRECT. SEE PLANS |
| AND ELEVATIONS AND REVISE AS REQUIRED. |
| D) COMPLETE ALL THE INFORMATION ON TOP OF FORM; PERMIT |
| OFFICE, JURISDICTION, ETC. |
| |
| 7- ARCHITECT TO PROVIDE HIS NAME AND LICENSE NUMBER IN |
| THE THE TITLE BLOCK AS REQUIRED BY SEC. 61G1-16.004 OF |
| FLORIDA ADMINISTRATIVE CODE. AND CHAPTER 481 FLORIDA |
| STATUTE. |
| SEC. 107.1 CITY AMENDMENTS TO FBC. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561)805-6712 |
| |