2013-05-20 17:00:19 | BUILDING PLAN REVIEW |
| PERMIT: 13030406 |
| ADD: 700 S ROSEMARY # 104 |
| CONT: CHANDLIER CONSTRUCTION |
| CONTACT:JOHN CHANDLIER |
| TEL: (561)791-6934 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| ACTION: DENIED |
| |
| NOTE THIS PERMIT IS WORK TO BE ACCOMPLISHED UNDER THE |
| LANDLORD ONLY BUT THERE ARE ISSUES TO BE WORKED OUT BY |
| BOTH THE TENANT AND LANDLORDAND TO WHICH THE LANDLORD |
| OR TENANT WILL TAKE RESPONSIBILITY. |
| |
| 1) COMPLIED. |
| |
| 2) COMPLIED |
| |
| |
| 3) ) 2010 EXST BLDG CODE 912.4.1 MEANS OF EGRESS FOR |
| CHANGE TO HIGHER HAZARD CATEGORY. |
| WHEN A CHANGE OF OCCUPANCY CLASSIFICATION IS MADE TO A |
| HIGHER HAZARD CATEGORY (LOWER NUMBER) AS SHOWN IN TABLE |
| 912.4, THE MEANS OF EGRESS SHALL COMPLY WITH THE |
| REQUIREMENTS OF CHAPTER 10 OF THE FLORIDA BUILDING |
| CODE, BUILDING. |
| |
| 4) COMPLIED, THE MAIN ENTRY / EXIT AND MONUMENTAL STAIR |
| MEETS THE REQUIREMENTS OF 1028.2. |
| |
| 5A) 2ND REQUEST. THE LIFE SAFETY PLANS HAVE SERIOUS |
| PROBLEMS SINCE THE MONUMETAL STAIRS CAN NOT BE USED FOR |
| EXITING AND SINCE THE 2ND FLOOR OCCUPANT LOAD IS AT 499 |
| OCCUPANTS, NEITHER THE STAIRS NOR THE DOORS AT THE BACK |
| OF THE BUILDING WILL HANDLE THESE OCCUPANT LOADS. THE |
| DESIGNER IS TAKING A 42 INCH DOOR AND STATING 200 |
| OCCUPANTS CAN EXIT THIS OPENING, WITH THE 2 DOORS MAXED |
| OUT AT 400 OCCUPANTS THERE ARE STILL 99 OCCUPANTS NOT |
| ACCOUNTED FOR IN EXITING THE 2ND FLOOR. THE BACK OF |
| HOUSE STAIR 1 & 2 DO NOT PROVIDE THE WIDTH OF THE STAIR |
| AND HOW MANY OCCUPANTS CAN USE THESE STAIRS AS A MENAS |
| OF EGRESS. |
| |
| 5B) THE SERVICE CORRIDOR IS ALSO CONSIDERED A EXIT |
| PASSAGEWAY SINCE IT IS A CONTINUATION OF THE VERTICAL |
| EXIT. MANY OF THE DOORS IN THIS EXIT PASSAGEWAY |
| DOORWAYS ARE NOT WIDE ENOUGH FOR THE NEW ASSEMBLY |
| OCCUPANCIES THAT NOW EXIST. FOR EXAMPLE TO THE SOUTH |
| THE SPACE WAS ORIGINALLY DESIGN FOR MERCANTILE |
| OCCUPANCY, THIS IS NOW GOING TO BE A RESTRAUNT WITH |
| DOUBLE THE OCCUPANT LOAD OF HOW THE EXIT PASSAGE WAY |
| WAS DESIGNED. THE SAME HOLD TRUE JUST TO THE NORTH, A |
| SECOND FLOOR NIGHTCLUB AND THE SECONDARY EXIT THAT |
| LEADS TO THE EXIT STAIRS. THE PROVIDED 499 FOR THE |
| SECOND FLOOR OCCUPANY LOADS THAT SHARE THE EXITING FOR |
| THIS COMMON EXIT PASSAGE WAY WILL NOT WORK WITH THE |
| CURRENT ARRANGEMENT. PLEASE NOTE PART OF THE EXIT |
| DISCHARGE A 4 FOOT WIDE SIDEWALK TO THE PARKING GARAGE |
| IS NOT WIDE ENOUGH ALSO FIGURE THE REQUIRED WIDTH OF |
| THE EXTERIOR STAIR WITHIN THE WALKWAY. THE OTHER |
| SIDEWALK THAT LEADS TO OKEECHOBEE BLVD IS NOT PROVIDED |
| IN ITS ENTIREITY NOR THE PROPOSED WIDTH. |
| 5C) THE CURRENT PLAN INDICATES THE OCCUPANT LOAD FROM |
| NV LOUNGE ALONE (340 OCCUPANTS) DOES NOT ALLOW FOR THE |
| OCCUPANT LOAD THAT NEEDS TO EXIT THE FIRST FLOOR. |
| |
| 6) ANOTHER ISSUE THAT IS BORDER LINE IS THE OCCUPANT |
| LOAD ON THE SECOND FLOOR AND A THIRD REQUIRED STAIRWAY |
| 2010 FBC-B TABLE 1021.1 IF 501 OCCUPANTS ARE LOCATED ON |
| THE 2ND FLOOR THEN A THIRD REQUIRED EXIT STAIR WILL |
| ALSO BE REQUIRED. UNTIL THE TENANT EXITING FROM THE |
| TENANT SPACE THE LANDLORD WORK CAN NOT BE APPROVED |
| SINCE THEEXITING THROUGH THE EXIT PASSAGEWAY IS UNDER |
| THE LANDLORD CONTROL. |
| |
| 7)COMPLIED> SPRINKLERS & SMOKE DRAFT CURTAIN TO BE |
| UNDER TENANT IMPROVEMENT PERMIT. |
| |
| 8) COMPLIED, TO BE UNDER TENANT SEPERATE PERMIT . SHEET |
| # A-3.0 INDICATES A NEW ROOF CURB PLEASE PROVIDE THE |
| MANUFACTURES CUT SHEETS ON THE NEW ROOF CURB FOR THIS |
| WIND SPEED, 170 MPH V-ULT. |
| |
| 9) THREE SETS OF PLANS ARE REQUIRED, THRESHOLD |
| BUILDING. |
| |
| 9A) THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) " |
| THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS |
| GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH |
| HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN |
| THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN |
| AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 |
| PERSONS. |
| |
| 109.3.6.1 THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL |
| INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A |
| THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION |
| PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL |
| INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING |
| AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR |
| THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE |
| OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE |
| SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT |
| THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE |
| WITH THE PERMITTED DOCUMENTS. |
| |
| 9B) THRESHOLD INSPECTOR: |
| WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES |
| DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL |
| INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA |
| STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS |
| CODE. |
| CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR |
| PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION |
| BEFORE THE PERMIT MAY BE ISSUED. |
| |
| 9C) THRESHOLD BLDG, REQUIRED STATEMENT: |
| W.P.B. AMENDMENT 109.3.6.4.4 ALL PLANS FOR THE BUILDING |
| WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE |
| ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT |
| THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S |
| KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE |
| APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE |
| LOCAL AUTHORITY IN |
| ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. |
| |
| 9D) A PLAN REVIEW STOP WILL BE PUT ON THIS PROJECT |
| UNTIL THESE ITEMS ARE COMPLETED AS REQUESTED BY THE |
| CHIEF BUILDING INSPECTOR KEN CONRAD: |
| |
| PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED |
| TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR |
| IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE |
| INSPECTIONS. |
| |
| 1) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY |
| FOR THIS TYPE OF CONSTRUCTION. |
| THIS MAY BE SUBMITTED TO KEN CONRAD BY E-MAIL. KEN |
| CONRAD: [email protected] |
| |
| 2) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' |
| OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE |
| RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS |
| SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE |
| WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, |
| AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| MEETING THE ABOVE CRITERIA. |
| CONTACT KEN CONRAD |
| TEL: 561-805-6666 |
| E-MAIL: [email protected] |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| |
| |