Plan Review Notes For Permit 13030296 |
Permit Number |
13030296 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2013-03-12 18:05:07 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. PRODUCT APPROVALS TO BE REVIEWED BY DESIGNER OF | | RECORD. | | | | 2. EITHER DESIGNER OF RECORD IS TO SPECIFY DESIGN | | PRESSURES OR THE FBC/ASCE7-10 TABLE WILL BE USED TO | | DETERMINE DESIGN PRESSURES. IN ORDER TO DO THIS, PLEASE | | PROVIDE ROOF PITCH, MEAN ROOF HEIGHT. | | | | 3. TWO DIFFERENT DESIGN PRESSURES ARE HIGHLIGHTED. | | PLEASE INDICATE FASTENING PROPOSED FOR ZONES 1, 2, AND | | 3. | | | | 4. PLEASE BE ADVISED THAT THIS REVIEW HAS BEEN DONE | | WITH 30# FELT AS THE UNDERLAYMENT. ANY OTHER | | UNDERLAYMENTS WILL REQUIRE A REVISION AS THIS STRUCTURE | | HAS AN ICYNENE INSULATION SYSTEM (ADVISORY ONLY). | | | | |
|