Permit Number |
13030090 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2013-03-05 12:55:58 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED. | | | | 2. PROVIDE BUILDING HEIGHT SO DESIGN PRESSURES CAN BE | | DETERMINED, FBC R 301. | | | | 3. IF THE BUILDING HAS A MEAN ROOF HEIGHT OF 15', WORST | | CASE DESIGN PRESSURE IS -95.7. THE ASSEMBLIES ON PAGES | | 22 AND 23 OF THE NOA MEET THIS PRESSURE. IF ANOTHER | | ASSEMBLY IS PROPOSED, PLEASE PROVIDE CALCULATIONS FOR | | THE ENHANCED FASTENING, SEE GENERAL LIMITATION #7 ON | | THE LAST PAGE OF THE NOA. CALCULATIONS ARE TO BE | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | CONSULTANT PER NOA LIMITATIONS. FBC R 301. | | | | 4. VALUE HAS BEEN ADJUSTED PER MARSHALL & SWIFT, FBC | | 109. | | | | 5. PROVIDE A PLAN SHOWING WHICH PORTION OF THE ROOF IS | | TO BE REPLACED. | | | | | | |
|