Date |
Text |
2013-02-28 11:24:47 | BUILDING PLAN REVIEW |
| PERMIT:13020210 |
| ADD: 701 S ROSEMARY AVE. SUITE # 316 |
| CONT: LAKEVIEW CONSTRUCTION |
| TEL: (561)635-6935 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: 02/28/2013 |
| ACTION: DENIED |
| |
| 1) THE COVER SHEET INDICATES ALL STOREFRONT TO BE FILED |
| UNDER SEPERATE PERMIT. PLEASE REMOVE THE MENTION OF |
| STOREFRONT FROM THESE PLANS SINCE IT IS NOT PART OF |
| THIS PERMIT. |
| 2010 WPB ADMINISTRATIVE CODE 107.2.1 INFORMATION ON |
| CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE |
| OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| AND EXTENT OF THE WORK PROPOSED... EXAMPLES ARE A200.00 |
| NOTE # 1 & A-600.00 ELEVATIONS. |
| |
| 2) SHEET A-200.00 THE TENANT SEPERATION WALLS: |
| 2A) SHEETS 700.00 - 703.00 PROVIDE THE WALL TYPES THAT |
| WERE IDENTIFIIED ON A-200.00. A COMMON NOTE ON WALL |
| SECTION TYPES ALIGN STUD KNOCK OUTS. ARE THESE DETAILS |
| INDICATING NEW WALLS NEXT TO THE EXISTING TENANT |
| SEPERATION WALLS WHERE THE STUD KNOK OUTS CAN BE |
| ALIGNED OR IS THE 5/8 INCH FIRE RATED DRYWALL BEING |
| REMOVED TO PUNCH NEW HOLES IN WHERE THEY DO NOT ALIGN? |
| 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. |
| |
| 2B) THE WALL TAGS FOR THE TENAT SEPERATION WALLS ARE TO |
| BE 1 HOUR PER 2010 FBC-B 709.6.1. ON THE SHEETS 700.00- |
| 702.00 THEY DO NOT INDICATE THEY ARE ONE HOUR FIRE |
| RATED. WALL TYPES L & P ARE INDICATED AS ONE HOUR |
| WALLS, WHY ARE THE OTHER WALL TAGS FOUND ON THE TENANT |
| SEPERATION DESIGNATED AS ONE HOUR? |
| |
| 2C) VARIOUS WALLS INDICATE BEING FURRED OUT WITH FIRE |
| RETARDANT TREATED 3/4 INCH PLYWOOD, PLEASE PROVIDE |
| COMPLIANCE WITH 2010 FBC-B 803.11.1 PLEASE PROVIDE |
| WHICH OF THE THREE OPTIONS WILL BE INSTALLED AT THE |
| SITE. |
| |
| 3) SHEET S010.00 DO PROVIDE THE WIND DESIGN CRITERIA IF |
| THE WINDOWS ARE TO BE PART OF THIS PERMIT. IF THE |
| WINDOWS ARE TO BE INSTALLED AS PART OF THIS PERMIT THEN |
| THE PRESSURES WILL NEED TO BE PROVIDED FOR THESE |
| OPENINGS AND TTHE HEIGHT FACTOR FOR A THREE STORY |
| BUILDING. 2010 FBC-B TABLE 1609.7(2). |
| |
| 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 5) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| WILL REQUIRE PRODUCT APPROVALS: |
| (31)(A) EXTERIOR DOORS. |
| (B) WINDOWS |
| (G) PRE-ENGINEERED A/C STANDS |
| |
| 6) SHEET SHEET S110.00 IS FOR BAR JOIST ROOF FRAMING |
| AND DETAILS FOR TYPICAL ROOFTOP MECHANICAL UNITS AND |
| OPENINGS THAT ARE NEW AND BEING CUT INTO THE ROOF DECK. |
| WHY IS THIS SHEET INCLUDED IN THESE PLANS, THERE IS TWO |
| STORIES OF R-2 AND BUSINESS OCCUPANCIES BETWEEN THE |
| FIRST FLOOR AND THE ROOF? IF ADDITIONAL AC UNITS ARE TO |
| BE ADDED THEY WOULD PROBABBLY BE SPLIT UNITS WITH THE |
| CONDENSORS ON THE ROOF. IN THAT CASE THE PRE-ENGINEERED |
| A/C STANDS WOULD NEED PRODUCT APPROVALS FOR THE WIND |
| SPEED AND EXPOSURE CATEGORY PLUS THE DETAILS FOR |
| FASTENING OF THE UNIT TO THE ROOF DECK AND OR BAR |
| JOIST. PLEASE BE AWARE OF 1609.8 ROOF TOP STRUCTURES |
| AND EQUIPMENT. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |