2013-01-28 14:39:42PROVISOS FOR EMERGENCY ROW CONSTRUCTION WORK:
  
 REPAIR THE CONCRETE SECTION TO 6" THICK 3000 PSI.
 PLEASE CALL ME DIRECTLY WHEN FINISH. REPAIR MUST BE
 DONE AS PER HOME OWNERS REQUEST.IT MUST NOT POSE A
 TRIPPING HAZARD ONCE CONCRETE IS POURED ANYWAY.
  
 IN DRY TRENCHES, BACKFILL MATERIAL SHALL BE PLACED
 EVENLY AND CAREFULLY AROUND AND OVER THE PIPE INTWELVE
 (12) INCH MAXIMUM LAYERS, EACH LAYER BEING THOROUGHLY
 COMPACTED, UNTIL ONE FOOT OF COVER STANDARDS FOR
 CONSTRUCTION AND USE OF RIGHTS-OF-WAY AND EASEMENTS
 EXISTS ABOVE THE CROWN OF THE PIPE. THE REMAINING
 TRENCH PORTION UP TO THE PAVEMENT BASE SHALL BE
 BACK-FILLED IN LAYERS NOT EXCEEDING EIGHT (8) INCHES
 WITH EACH LAYER BEING COMPACTED.
  
 THANK YOU!
  