Plan Review Notes For Permit 13010727 |
Permit Number |
13010727 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2013-02-07 13:53:39 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE INSTALLATION SCHEDULE THAT WAS SUBMITTED DOES | | NOT PROVIDE ALL OF THE INFORMATION THAT IS REQUIRED TO | | DETERMINE THAT THE INSTALLATION OF THE STORM PANELS | | WILL MEET THE WINDLOAD REQUIREMENTS OF FBCR 301.2.1. | | THE MOUNTING TYPE (SHEET 2, 4 OF THE DRAWINGS), TYPE OF | | SUBSTRATE THAT YOU ARE ANCHORING TO, TYPE OF ANCHORS | | YOU WILL USE, ANCHOR SPACING, GLASS SEPARATION, EDGE | | DISTANCE, SHUTTER SPAN ARE NEEDED. READ THE PRODUCT | | APPROVAL DRAWINGS TO SEE WHAT WILL WORK FOR YOUR | | SITUATION AND SUPPLY THAT INFORMATION IN THE SCHEDULE. | | THE FOLLOWING IS A LINK TO THE SAMPLE INSTALLATION | | SCHEDULE ON THE CONSTRUCTION SERVICES WEBSITE THAT YOU | | CAN PRINT OUT AND USE: | | HTTP://WPB.ORG/DEVELOPMENT/CONSTRUCTION/PDF/SCHEDULE_FO | | R_INSTALLATION.PDF | | | | 2) THE WORK DESCRIPTION ON THE APPLICATION SPECIFIES | | SHUTTERS ON 20 OPENINGS AND THE SCHEDULE THAT WAS | | SUBMITTED HAS 20 OPENINGS ON THE MAIN HOUSE AND 11 ON | | THE GUEST HOUSE. THE VALUE FOR INSTALLING THE STORM | | PANELS IS $1200.00. PLEASE CLARIFY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|