Plan Review Notes
Plan Review Notes For Permit 13010504
Permit Number 13010504
Review Stop B
Sequence Number 3
Notes
Date Text
2013-04-22 13:28:11 
 PERMIT: 13010504
 ADD: 631 EVERNIA ST.
 CONT: KAUFMAN LYNN
 TEL: (561)361-6700
  
  
 EVERNIA PLACE
 AFFORDABLE SENIOR HOUSING
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 3RD REVIEW
 APRIL 22/ 2013
 ACTION: DENIED
  
 4TH REVIEW APRIL 24/2013
  
 1) 3RD REVIEW IN PROCESS OF UNITY OF TITLE, ENGINEERING
 WILL NOTIFY ME ONCE THE UNITY OF TITLE HAS BEEN
 RECORDED.
  
 THE CIVIL PLAN C-2 APPEARS THAT THE LOTS ARE TO BE
 UNIFIED, A TITLE OF UNITY IS REQUIRED. UNITY OF TITLE.
 THE PROPOSED BUILDING STRUCTURE TRANSGRESSES LEGAL
 BOUNDARY LINES BETWEEN THE LOTS WHICH COMBINE TO FORM
 'THE SITE'. A 'UNITY OF TITLE' SHALL BE RECORDED AT THE
 COUNTY COURTHOUSE. SUBMIT A COPY OF THE RECORDED 'UNITY
 OF OF TITLE' DOCUMENT SO THAT FBC TABLE 601 BOUNDARY
 LINE REQUIREMENTS MAY BE DEEMED NOT APPLICABLE.
 SEE WEBSITE FOR APPLICATION:
 HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP
 "APPLICATION FOR UNITY OF TITLE"
  
 HTTP://WWW.WPB.ORG/ENGINEERING/UPLOADS/2010-10-12-14-45
 -38-UNITYOFTITLE3.PDF
  
 VINCENT J NOEL
 SURVEYOR/REAL ESTATE SUPERVISOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET
 WEST PALM BEACH, FL 33401
 PHONE: 494-1040 EXT: 1096
 FAX: 494-1116
 E-MAIL: [email protected]
  
 *********************************************
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
 2) 3RD REQUEST! THIS BUILDING IS CONSIDERED A THRESHOLD
 BUILDING, (3) SETS OF PLANS, PRODUCT APPROVALS WILL
 REQUIRED, ONE SET FOR THE SPECIAL INSPECTOR, ONE FOR
 THE FIELD, AND A COPY WILL BE KEPT ELECTRONICALLY BY
 THE BUILDING DEPARTMENT, FOR OUR RECORDS.
  
 THRESHOLD INSPECTION PLAN FL S. S. 553.71(7) "
 THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH
 HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN
 THE
 FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN AREA
 AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS.
  
 2A) 2ND REQUEST. 109.3.6.1 THE ENFORCING AGENCY SHALL
 REQUIRE A SPECIAL INSPECTOR TO PERFORM STRUCTURAL
 INSPECTIONS ON A THRESHOLD BUILDING PURSUANT TO A
 WRITTEN STRUCTURAL INSPECTION PLAN PREPARED BY THE
 ENGINEER OF RECORD. THE STRUCTURAL INSPECTION PLAN MUST
 BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE
 ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A
 THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL
 INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION
 PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE
 ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED
 DOCUMENTS.
  
 2B) 3RD REQUEST. THRESHOLD INSPECTOR: WPB AMENDMENT
 109.3.6.2 W.P.B. CONSTRUCTION SERVICES DEPARTMENT
 REQUEST FOR THRESHOLD BUILDINGS A SPECIAL INSPECTOR AS
 REQUIRED BY FL S S 553.79(5) FLORIDA STATUTES TO THE
 MINIMUM INSPECTIONS REQUIRED BY THIS CODE.
 CONTACT KEN CONRAD MANAGER OF THE SPECIAL INSPECTOR
 PROGRAM AT (561)805-6666 FOR FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
  
 2C) COMPLIED. THRESHOLD BLDG, REQUIRED STATEMENT:
 W.P.B. AMENDMENT 109.3.6.4.4 ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE
 LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE.
  
 2D) 3RD REQUEST. 109.3.6 THRESHOLD BUILDINGS, OPERATING
 GUIDELINES FOR THRESHOLD INSPECTORS #26. ASSURE THAT
 THE DESIGNER HAS REQUIRED ON THE PLANS OR
 SPECIFICATIONS ONE MATERIAL, APPROVED FOR FIRE STOPPING
 PENETRATIONS, FOR WALLS AND CEILINGS. ALL TRADES THAT
 PENETRATE THE FIRE RATED SLAB WILL NEED TO USE ONE
 PRODUCT THAT IS TO BE SPECED OUT BY THE DESIGNER OF
 RECORD, SO ALL PENETRATIONS WILL REQUIRE THE
 ENGINEERING SHEETS FOR THAT SPECIFIC PRODUCT AND
 APPLICATION.
  
 2E) A THRESHOLD PLAN REVIEW STOP WILL BE PUT ON THIS
 PROJECT UNTIL THESE ITEMS ARE COMPLETED AS REQUESTED BY
 THE CHIEF BUILDING INSPECTOR KEN CONRAD:
  
 PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED
 TELEPHONE INSPECTIONS LINE
 (561) 805-6700) FOR IN-PROGRESS INSPECTIONS FOR
 AUDITING OF JOBSITE INSPECTIONS.
  
 2E)(1) 2ND REQUEST. THE CONTRACTOR WILL PRODUCE A JOB
 SUMMARY OR HISTORY FOR THIS TYPE OF CONCRETE
 RESTORATION. THIS MAY BE SUBMITTED TO KEN CONRAD BY
 E-MAIL. KEN CONRAD: [email protected]
  
 2E)(2) 3RD REQUEST. FOR THE SPECIAL INSPECTOR PLEASE
 PROVIDE A RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS
 PROJECT. THE RESUME' MUST BE ACCOMPANIED BY ALL
 CERTIFICATES AS SPECIFIED HEREIN. THE BUILDING OFFICIAL
 OR HIS DESIGNEE WILL REVIEW THE RESUME'. AFTER THE
 RESUME' IS REVIEWED, AN INTERVIEW WILL BE SCHEDULED.
 UNDER NO CIRCUMSTANCES WILL AN INSPECTOR BE INTERVIEWED
 FOR WORK WITHOUT FIRST MEETING THE ABOVE CRITERIA.
 CONTACT KEN CONRAD
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 3) SOILS REPORT BY ARDAMEN 11/19/2012, & 12/27/2012.
 2010 FBC-B 1803.2 SOILS INVESTIGATION ARE PROVIDED WILL
 REQUIRE A PEDS SIGNATURE SINCE THEY ARE SIGNED AND
 SEALED.
  
 4-5) COMPLIED.
  
 6) 3RD REQUEST 2010 FBC 107.3.4.1 PRODUCT APPROVALS.
 THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE
 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP) BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 7) 2ND 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 CORNELL GAGARGE DOOR PLEASE CIRCLE WHICH TYPE OF DOOR
 IS TO BE INSTALLED AND ASSOCIATED PRESSURES.
  
 (B) WINDOWS/ MULLIONS PLEASE CIRCLE WHICH APPLICATIONS
 WILL BE USED FOR TYPE OF GLAZING SIZE OF WINDOW AND
 ASSOCIATED PRESSURES, PLEASE INDICATE IF STEEL
 RE-INFORCEMENT WILL BE REQUIRED FOR THE ASSOCIATED
 PRESSUES.
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES ROOFING MEMBRANE
 COVER SHEET IS ACTUALLY ROOFING INSULATION, NOT THE
 ROOFING MEMBRANE, NO PRODUCT APPROVAL WAS SUBMITTED FOR
 THE ROOF COVERING.
 METAL ROOFING PLEASE CIRCLE WHICH SUB-SYSTEM IS TO BE
 INSTALLED, AND IF ENHANCED FASTENING WILL BE ALLOWED
 SEE ALLOWED. NOTE ONLY THE COVER SHEET WAS UPLOADED,
 NEITHER THE EVALUATION REPORT WAS UPLOADED NOR THE
 INSTALATION INSTRUCTIONS.
 (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C
 STANDS
  
 8) 2COMPLIED.
  
 9) SHEET LS-101:
  
 9A-F) COMPLIED .
  
  
 10) SHEET A-201:
 10A-B) COMPLIED.
 .
 10C) BUILDING PROVISO: TO BE SUPPLIED AS A LOW VOLTAGE
 PERMIT. PROVIDE COMPLIANCE WITH F] 915.1 GENERAL.
 EMERGENCY RESPONDER RADIO COVERAGE SHALL BE PROVIDED IN
 ALL NEW BUILDINGS IN ACCORDANCE THE FLORIDA FIRE
 PREVENTION CODE.
  
 10D)(1) 3RD REQUEST. MACHINE ROOM-LESS ELEVATORS SHEET
 A-621. KONE ECOSPACE. WILL NEED MANUFACTURERS
 REQUIREMENTS FOR INSTALLATION. MAY STILL NEED TO
 INCORPORATE HOIST WAY VENTING REQUIREMENTS FOUND IN
 2010 FBC-B 3004.
  
 10D) (2) COMPLIED. PROVIDE COMPLIANCE WITH 3002.4
 ELEVATOR CAR TO ACCOMMODATE AN AMBULANCE STRETCHER.
  
 11) SHEET A202 TRASH CHUTE
 11A)3RD REQUEST. SEMI COMPLIED, LS-103/ LS-104. THE
 NORTH STAIRWELL INDICATES THE TRASH CHUTE ACTUALLY
 PENETRATING THE 2 HOUR FIRE RATED STAIR ENCLOSURE.
 PLEASE REVIEW 2010 FBC-B 1022.4 PENETRATIONS INTO &
 THROUGH AN EXIT ENCLOSURE. PLEASE REVIEW THE
 REQUIREMENTS FOR TERMINATION ROOM 708.13.4 ALSO SEE
 708.8. 708.8 DEALS WITH HOW THE TRASH CHUTE WILL
 PENETRATE THE 2 HOUR SHAFT.T .
  
 11B) COMPLIED.
  
 11C) COMPLIED.
  
 11D) 4/24/13 COMPLIED. 4TH REVIEW.
  
 11E) 3RD REQUEST. 4/24/2013 4TH REVIEW. SHEET A-601
 DETAIL # 1 TRASH CHUTE SHAFT STOPS AT THE BOTTOM OF THE
 2ND FLOOR, IT DOES NOT CONTINUE THROUGH TO THE 1ST
 FLOOR ALTHOUGH THE SHAFT DOES PENETRATE THE 2ND FLOOR
 ASSEMBLY AND 1ST FLOOR WALL. PLEASE SEE 708.11
 ENCLOSURE AT THE BOTTOM . TRASH CHUTE DETAILS WERE
 UPLOADED AND DEPICT A 2 HR HEAT ACTIVATED ACCORDIAN
 FIRE DAMPER. PLEASE PROVIDE THE MANUFACTURERS
 INSTALATION INSTRUCTIONS THAT WILL THE DAMPER TO BE
 INSTALLED ON A 45 DEGREE ANGLE, IT IS DEPICTED IN THERE
 LITERATURE AS A HORIZONTAL APPLICATION.
  
 11F) COMPLIED.
  
 11G) 3RD REQUEST. 4TH REVIEW 4/24/13 2010 FBC-B
 708.13.6. AUTOMATIC SPRINKLERS SYSTEM. AN APPROVED
 AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED IN
 ACCORDANCE WITH SECTION 903.2.11.2. F] 903.2.11.2
 RUBBISH AND LINEN CHUTES.BUILDINGS WITH SHUTES GREATER
 THAN 3 STORIES SHALL HAVE ADDTIONAL HEADS AT
 ALTERNATING FLOORS. NEITHER THE TRASH CHUTE NOR FIRE
 SPRINKLER DRAWINGS HAVE ONLY ONE FIRE SPRINKLER HEAD AT
 THE 3RD FLOOR.
 2010 FBC-B 903.2.11.2. AN AUTOMATIC SPRINKLER SYSTEM
 SHALL BE INSTALLED AT THE TOP OF RUBBISH AND LINEN
 CHUTES AND IN THEIR TERMINAL ROOMS. CHUTES EXTENDING
 THROUGH THREE OR MORE FLOORS SHALL HAVE ADDITIONAL
 SPRINKLER HEADS INSTALLED WITHIN SUCH CHUTES AT
 ALTERNATE FLOORS. CHUTE SPRINKLERS SHALL BE ACCESSIBLE
 FOR SERVICING. PROVIDE DETAILS FOR THE SERVICING OF THE
 FIRE SPRINKLERS.
  
 12) COMPLIED.
  
 13) 2ND REQUEST. SHEET A450 DETAILS 1-3 HAVE GENERAL
 NOTES, A602, A609, A-620 AT DETAILS INDICATING SOLID
 SHEATHING THEN NOTES 1 & 2 THE SPECIFIC NOTE INDICATES
 THE USE OF DENSE-DECK. PLEASE BE AWARE OF PRESSURES
 FROM THE PRODUCT APPROVAL WILL BE FOR 3/4 INCH OR 5/8
 CDX PLYWOOD NOT FOR DENSE DECK, IF PLYWOOD IS USED IT
 NEEDS TO BE FIRE RETARDENT TREATED PLYWOOD SEE 603.1.1.
  
 4/24/13 NOTE HAVE BEEN CHANGED TO 5/8 INCH CDX PLYWOOD,
 NO MENTION OF FIRE RETARDENT TREATED PLYWOOD.
  
 13) COMPLIED.
  
 14A) COMPLIED.
  
 15) COMPLIED.
  
 16) COMPIED.
  
 17) COMPLIED.
  
 18A-B COMPLIED.
  
 18C) 3RD REQUEST.4TH REVIEW 4/24/13/ PLEASE SHOW
 COMPLIANCE WITH 2010 FBC-B 1207.3 STRUCTURE BORNE
 SOUND, FLOOR CEILING ASSEMBLIES TO HAVE A INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50, (45 IF FIELD
 TESTED). THE PLANS DO NOT PROVIDE WHAT FLOOR FINISHES
 WILL OCCUR IN THTE TENANT SUITES NOR THE COMMON AREAS
 OR ELECTRICAL ROOMS ...
  
 19) COMPLIED
  
 20)COMPLIED.
  
 21) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 *****INFORMATIONAL*****PLEASE!!!!!!!: WHEN RESUBMITTING
 PLANS PLEASE INDICATE THE REVISION & REMOVE & REPLACE
 ANY PAGES AS NECESSARY. A TRANSMITTAL LETTER LISTING
 THE ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION
 OF THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
  
  
  
  
  
  