2013-01-28 08:34:07****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 A SCHEDULE WAS PROVIDED BUT IS LACKING SOME INFORMATION
 SUCH AS EDGE DISTANCE, ANCHOR SPACING, PANEL
 ORIENTATION, ETC. IT IS ACCEPTABLE TO USE AN ALTERNATE
 FORM IF IT CONTAINS ALL INFORMATION REQUIRED TO
 DETERMINE WHETHER OR NOT THE PROPOSED INSTALLATION
 COMPLIES WITH THE REQUIREMENTS OF THE PRODUCT APPROVAL.
  
 IF PANELS ARE INSTALLED HORIZONTALLY, PLEASE NOTE THAT
 THE SUBSTRATE WOULD BE CONCRETE BLOCK RATHER THAN
 CONCRETE (GROUTED CELLS) UNLESS YOU HAVE EVIDENCE THAT
 ALL OPENINGS HAVE FORMED AND POURED COLUMNS ON EACH
 SIDE OR WAS CONSTRUCTED OF CONCRETE PANELS.
  
 2. THIS PARCEL APPEARS TO BE LOCATED IN EXPOSURE D, SEE
 FBC RESIDENTIAL 301.
  