2013-10-28 17:24:37APPROVED WITH EXCEPTION
  
 THE PRODUCT APPROVAL SUBMITTED FOR THE FRENCH DOORS IS
 NOT IMPACT RATED. THE EGRESS DOOR CAN NOT BE SHUTTERED.
 SUBMIT PRODUCT APPROVALS WITH LARGE MISSILE IMPACT
 RATING FOR THE EGRESS DOOR. FOR THE OTHER DOORS SUBMIT
 2 SETS OF PRODUCT APPROVALS FOR STORM PANELS WITH
 INSTALLATION SCHEDULES.
  
 THE PRODUCT APPROVAL FOR THE SANTEFE CLAY BARREL TILE
 ALLOWS TWO ATTACHMENT METHODS WITH ACCEPTABLE
 ATTACHMENT RESISTANCE. THEY ARE MORTAR OR 3M AH-160
 ROOF TILE ADHESIVE. IF THE AH-160 ADHESIVE IS USED
 SUBMIT TWO SETS OF PRODUCT APPROVALS.
  
 CORRECT REDLINED MARK-UPS ON THE PLANS.