Plan Review Notes For Permit 12120698
Permit Number 12120698
Review Stop B
Sequence Number 2
Notes
Date Text
2013-02-12 15:20:462010 FBC
  
 DENIED BY BUILDING
  
 1) THE WINDLOAD PRESSURES FOR THE OVERHEAD GARAGE DOOR
 SPECIFIED ON SHEET S-1 OF THE PLANS IS HIGHER THAN
 REQUIRED. THE PRODUCT APPROVAL THAT IS SUBMITTED IS
 REQUIRED TO MEET OR EXCEED THE PRESSURES SPECIFIED ON
 THE PLANS. DCA RULE 9N-3.
  
 2) SUBMIT TWO COPIES OF A SURFACE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBCR 401.3. THESE CAN BE SUBMITTED WITH
 EACH PERMIT APPLIED FOR UNDER THE MASTER.
  
 3) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR EXTERIOR
 WINDOWS, DOORS, OVERHEAD GARAGE DOORS, ROOFING
 MATERIAL, BLOCK LINTELS, TRUSS ANCHORS, MULLIONS,
 HARDI-PLANK SIDING, ETC. AS REQUIRED BY DCA RULE 9N-3.
  
 4) THE PRODUCT APPROVALS ARE REQUIRED TO REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PER CITY
 AMENDMENTS 107.3.4.1.
  
 5) SUBMIT TWO SETS OF SIGNED AND SEALED TRUSS DRAWINGS
 AND LAYOUTS THAT HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD. FBCR 802.1.6.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]