2012-12-14 08:50:01RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 09-0224.01 SUBMITTED. NEED THE NAIL ENHANCING
 CALCULATIONS TO MEET THE DESIGN PRESSURES REQUIRED BY
 SEC. 1609.4.3 OF 2010 FBC.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATIONS WAS UPDATED AS REQUIRED BY SEC. 109.3
 OF CITY AMENDMENTS TO FBC. OWE THE PERMIT FEE BALANCE
 OF S$35.68. PAY THIS AT TIME OF PERMIT PICK UP.
  