Plan Review Notes
Plan Review Notes For Permit 12110512
Permit Number 12110512
Review Stop B
Sequence Number 2
Notes
Date Text
2013-01-04 15:42:17****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS,
 SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING
 CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR
 BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING
 CANNOT BE REDUCED BY MORE THAN 5%.
  
 2ND REVIEW, AS AWNING WINDOWS HAVE A REMOVABLE PANEL,
 THE PROPOSED WINDOWS DO NOT COMPLY WITH EMERGENCY
 ESCAPE AND RESCUE REQUIREMENTS. A REVISED FLOOR PLAN
 WAS NOT SUBMITTED, BUT THE TALLEST WINDOW IS 49".
 PLEASE REVISE PLAN TO SHOW ROOM DESIGNATIONS AND WINDOW
 PROPOSED WHICH COMPLIES WITH FBC R310.
  
  
  