Plan Review Notes For Permit 12100933 |
Permit Number |
12100933 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2012-11-06 12:26:15 | ****PROVISO**** | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | PROVIDE EMERGENCY MEANS OF ESCAPE, FBC R310.4: | | | | THE TEMPORARY INSTALLATION OR CLOSURE OF STORM | | SHUTTERS, PANELS, AND OTHER APPROVED HURRICANE | | PROTECTION DEVICES SHALL BE PERMITTED ON EMERGENCY | | ESCAPE AND RESCUE OPENINGS DURING THE THREAT OF A | | STORM. SUCH DEVICES SHALL NOT BE REQUIRED TO COMPLY | | WITH THE OPERATIONAL CONSTRAINTS OF SECTION R310.1.4. | | | | WHILE SUCH PROTECTION IS PROVIDED, AT LEAST ONE MEANS | | OF ESCAPE FROM THE DWELLING OR DWELLING UNIT SHALL BE | | PROVIDED. THE MEANS OF ESCAPE SHALL BE WITHIN THE FIRST | | FLOOR OF THE DWELLING OR DWELLING UNIT AND SHALL NOT BE | | LOCATED WITHIN A GARAGE WITHOUT A SIDE-HINGED DOOR | | LEADING DIRECTLY TO THE EXTERIOR. OCCUPANTS IN ANY PART | | OF THE DWELLING OR DWELLING UNIT SHALL BE ABLE TO | | ACCESS THE MEANS OF ESCAPE WITHOUT PASSING THROUGH A | | LOCKABLE DOOR NOT UNDER THEIR CONTROL. | | | | ****INSPECTOR TO VERIFY MEANS OF ESCAPE**** | | | | |
|