2012-10-17 13:47:21RESIDENTIAL (R3) REROOF BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC-RESIDENTIAL.
  
 1- SHINGLES ON A 3/12 PITCH REQUIRES 2 LAYERS OF
 UNDERLAYMENT. SEC. R905.2.2. IF CONTRACTOR IS PROPOSING
 TO USE SELF-ADHERING UNDERLAYMENT APPLIED DIRECT TO THE
 DECK, THEN, REQUEST FOR APPROVAL FOR THIS METHOD NEEDS
 TO BE SUBMITTED FOR THE BUILDING OFFICIAL APPROVAL
 UNDER ALTERNATIVE MATERIALS, DESIGN AND METHODS OF
 CONSTRUCTION SEC. 104.11 CITY AMENDMENTS TO FBC.
  
 2- FLAT ROOF NOA SUBMITTED: CLEARLY IDENTIFY WHICH
 APPROVED ASSEMBLY IS GOING TO BE INSTALLED. SEC.
 107.2.1.2 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712