2012-12-14 13:34:27 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- SHEET 1.2: | | A) UTILITY AREA NEW OUTDOOR STEPS: (1) PROVIDE COMPLETE | | HANDRAILS DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE | | WITH LIVE LOAD ON TABLE R301.5 AND SEC. R311.7.7 OF | | 2010 FBC-RESIDENTIAL. ENGINEER PLANS ONLY SAYS NEW | | HANDRAIL DESIGNED BY OTHERS. NO INFORMATION WAS | | PROVIDED FOR REVIEW. | | | | B) NEW STEPS ON REAR SHOWS TREAD SIZE AS 8". MINIMUM | | TREAD SIZE IS 10". SEE SEC. R311.7.4.2 OF 2010 | | FBC-RESIDENTIAL AND REVISE AS REQUIRED. | | | 2012-12-14 13:32:08 | 12/14/12 AS PER PHONE CONVERSATION WITH KARI IT'S OK TO | | ISSUE THE PERMIT WITH PROVISO AND REVISION FEES WILL | | APPLY. ALSO, PER KARI TOTAL WORK VALUE IS $16,000. JG. |
|