Plan Review Notes For Permit 12100028 |
Permit Number |
12100028 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2012-12-07 11:03:29 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW | | COMMENTS. | | CODE; 2010 FBC. | | | | 1- SHEET 1.2: | | A) UTILITY AREA NEW OUTDOOR STEPS: (1) PROVIDE COMPLETE | | HANDRAILS DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE | | WITH LIVE LOAD ON TABLE R301.5 AND SEC. R311.7.7 OF | | 2010 FBC-RESIDENTIAL. ENGINEER PLANS ONLY SAYS NEW | | HANDRAIL DESIGNED BY OTHERS. NO INFORMATION WAS | | PROVIDED FOR REVIEW. | | | | B) NEW STEPS ON REAR SHOWS TREAD SIZE AS 8". MINIMUM | | TREAD SIZE IS 10". SEE SEC. R311.7.4.2 OF 2010 | | FBC-RESIDENTIAL AND REVISE AS REQUIRED. | | | | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW BASED ON THE SCOPE OF WORK TO BE DONE. SEC. 109.3 | | CITY AMENDMENTS TO FBC. UPDATE VALUATIONS AS REQUIRED. | | VALUATION TO INCLUDE ALL PROFESSIONAL DESIGN FEES, ALL | | LABOR AND MATERIALS AND CONTRACTOR'S OVERHEAD AND | | PROFIT. PROVIDE COPY OF SIGNED CONTRACT SIGNED BY OWNER | | AND CONTRACTOR. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|