Plan Review Notes For Permit 12090727 |
Permit Number |
12090727 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2012-10-18 14:24:00 | 2010 FBC | | | | PLUMBING PROVISO | | | | DUE TO CHANGES TO THE SWIMMING POOL CODES SINCE THE | | POOL WAS ORIGINALLY PERMITTED UNDER THE 2004 FBC, THE | | FOLLOWING REQUIREMENTS MUST BE MEET. | | | | 1) ANSI/APSP-7 2006 SECTION 4.4 (2010 FBCR4101.6.3) | | LIMITS THE WATER VELOCITY IN THE MAIN DRAIN BRANCH | | SUCTION TO 6 FT/SEC WHEN ONE OF THE PAIR IS BLOCKED. | | THE BRANCH PIPING FOR THIS POOL IS TWO INCHES. | | THEREFORE, THE MAXIMUM FLOW RATE FOR THE PUMP CAN NOT | | EXCEED 60 GPM. | | | | 2) THE 2010 FBC ENERGY CONSERVATION SECTION 403.9.4 | | REQUIRES POOL PUMPS AND POOL PUMP MOTORS WITH A TOTAL | | HORSE POWER (HP) OF GREATER THAN OR EQUAL TO 1 HP TO | | HAVE THE CAPABILITY OF OPERATING AT TWO OR MORE SPEEDS. | | THE LOW SPEED SHALL HAVE A ROTATION RATE OF NO MORE | | THAN 1/2 OF THE MOTOR'S MAXIMUM ROTATION RATE. THE PUMP | | MOTOR SHALL NOT BE SPLIT-PHASE, SHADED POLE OR | | CAPACITOR START-INDUCTION RUN TYPES. |
|