2012-11-19 17:18:45 | 11-19-2012 - ADDITIONAL INFORMATION HAS BEEN PROVIDED / |
| REPLACEMENT OF PLAN ELEMENTS AS PER THE REQUEST OF |
| ENGINEERING SERVICES. |
| NEW PLANS WILL NOT LONGER USE THE ALLEYWAY TO ACCESS |
| THE SITE AS PROPOSED ON JUNE 21,2011 PLANS. |
| |
| APPROVED AS-NOTED: |
| |
| #1 CITY OF WPB STANDARD DETAILS FOR PAVEMENT AND CURB |
| (SEE ATTACHED). |
| |
| #2 PAVEMENT MATERIAL FOR OFF-SITE PARKING MUST BE A |
| MINIMUM OF 1 1/2 INCH TYPE S-1 ASPHALTIC CONCRETE (TACK |
| BETWEEN COURSES) WITH6" THICK LIMEROCK OR CRUSHED |
| CONCRETE BASES SHALL BE TEN INCHES (10") THICK. |
| LIMEROCK OF THE MIAMI FORMATION SHALL BE USED, HAVING A |
| MINIMUM PERCENTAGE OF CARBONATES OF CALCIUM AND |
| MAGNESIUM OF 70, UNLESS OTHERWISE APPROVED. CRUSHED |
| CONCRETE SHALL HAVE A MAXIMUM SIZE OF 1". CWPB STANDARD |
| DETAILS. |
| (HTTP://WWW.WPB.ORG/ENGINEERING/ENG_STANDARDS.HTM) |
| (SUBSTITUTION TO THIS MATERIAL WOULD BE 6" THICK |
| CONCRETE 3000PSI WITH FIBER). |
| |
| #3 CURB/GUTTER |
| ALL CURB ELEMENTS SHALL HAVE A FOUNDATION OR "PAD" WITH |
| A MINIMUM LBR RATIO OF 70 AND SHALL BE |
| AT LEAST 4" IN THICKNESS, EXTENDING 6" (MIN.) BEYOND |
| THE EDGES OF THE CONCRETE, COMPACTED TO 98% |
| OF MAXIMUM DENSITY, PER AASHTO T-180, UNLESS OTHERWISE |
| APPROVED. |
| |
| #4 SITE AREA AS PER PLAN DIMENTIONS ARE AS FOLLOWS: |
| TOTAL SITE AREA = 6,475.00 SF |
| TOTAL BUILDING AREA 897.20 SF |
| TOTAL IMPERVIOUS AREA = 758SF |
| TOTAL PERVIOUS AREA = 4,819.80SF |
| |
| #5 ROW AREAS DISTURBED BY CONSTRUCTION SHALL BE SODDED |
| WITH BAHIA GRASS OR ST. AUGUSTINE FLORATAM GRASS |
| STANDARDS FOR CONSTRUCTION AND USE OF PUBLIC |
| RIGHTS-OF-WAY AND EASEMENTS" AUTHORIZED BY ORDINANCE |
| NUMBER 4198-09. |
| |
| #6 SIDEWALKS |
| SIDEWALKS SHALL BE OF PORTLAND CEMENT CONCRETE, A |
| MINIMUM OF 3,000 PSI, FOUR INCHES (4") THICK (FIBER), |
| AND FIVE FEET (5.0') WIDE. SIDEWALKS SHALL EXTEND |
| ACROSS DRIVEWAYS, AT WHICH LOCATIONS THEY SHALL |
| HAVE A MINIMUM THICKNESS OF 6" (FIBER). ANY NECESSARY |
| OBSTRUCTION SHALL BE PLACED SO AS TO MAINTAIN THE |
| MAXIMUM CLEAR WIDTH AND MEET THE REQUIREMENTS OF THE |
| AMERICANS WITH DISABILITIES ACT. |
| SIDEWALKS SHALL BE MAINTAINED BY THE CITY. THE ABUTTING |
| PROPERTIES SHALL MAINTAIN DRIVEWAYS, |
| INCLUDING THE SIDEWALK SECTIONS. |
| SIDEWALKS SHALL HAVE A TRANSVERSE SLOPE OF 2% PER FOOT |
| DOWN TOWARD THE SWALE OR GUTTER AND SHALL |
| BE GIVEN TRANSVERSE BROOM FINISH. |
| |
| RAMPS FOR PEOPLE WITH DISABILITIES SHALL BE PLACED AT |
| ALL CORNER LEADING TO CROSSWALK. |
| |
| #7 OFF-SITE PARKING MUST BE STRIPPED USING 4" THICK |
| STRIPES. |
| |
| #8 SOLID WASTE - WILL BE PICKED UP BY CURB SIDE PICKUP. |
| OWNER WILL BE RESPONSIBLE TO SET GARBAGE BY THE CURB. |
| |
| #9 OWNER WILL OBTAIN A PLUMBING PERMIT TO INSTALL A |
| DOMESTIC WATER REDUCED PRESSURE PRINCIPLE ASSEMBLY FOR |
| COMMERCIAL ESTABLISHMENT |
| CWPB CODE SEC. 90-33. - REGULATION OF CROSS CONNECTION. |
| |
| #10 NOTED ON PLANS: "PARKING SPACES IN CITY OF WPB |
| RIGHT-OF-WAYS WILL NOT BE ALLOCATED FOR EXCLUSIVE USE". |
| |
| #11 DETECTABLE WARNING: PROVIDE DETECTABLE WARNINGS IN |
| ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT |
| STANDARDS FOR TRANSPORTATION FACILITIES, SECTION 705. |
| USE DETECTABLE WARNINGS CONSISTING OF MATERIALS |
| INTENDED FOR EXTERIOR USE SUBJECT TO ROUTINE PEDESTRIAN |
| TRAFFIC AND OCCASIONAL VEHICULAR TRAFFIC. USE |
| DETECTABLE WARNINGS WITH SIZE AND PATTERN SHOWN IN THE |
| PLANS COMPRISED OF TRUNCATED DOMES ALIGNED IN PARALLEL |
| ROWS IN ACCORDANCE WITH THE DESIGN STANDARDS, INDEX NO. |
| 304. DO NOT USE DETECTABLE WARNINGS WITH A DIAGONAL |
| PATTERN. |
| |
| #12 FINAL INSPECTION AND ACCEPTANCE: |
| AFTER CONSTRUCTION IS COMPLETED AND ALL CERTIFICATIONS, |
| RECORD DRAWINGS AND OTHER REQUIREDDOCUMENTS HAVE BEEN |
| SUBMITTED TO THE ENGINEERING SERVICES DEPARTMENT, THE |
| PERMITTEE SHALL REQUEST A FINAL INSPECTION OF THE |
| PROJECT. THE ENGINEERING SERVICES DEPARTMENT AND ALL |
| OTHER INTERESTED PARTIES SHALL JOINTLY PERFORM SUCH |
| INSPECTION TO DETERMINE THE ACCEPTABILITY OF THE |
| PROJECT FOR MAINTENANCE. FOLLOWING THE INSPECTION, ANY |
| NOTED DEFECTS WILL BE CORRECTED BY THE PERMITTEE, THIS |
| WILL MARK THE START OF THE ONE-YEAR WARRANTEE PERIOD. |
| |
| MANUEL JULIAN GONZALEZ |
| ENGINEERING PROJECT COORDINATOR |
| ENGINEERING SERVICES DEPARTMENT |
| 401 CLEMATIS STREET, 4TH FLOOR |
| WEST PALM BEACH, FL 33401 |
| (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) |
| MAIN PHONE: (561) 822-1200 |
| DIRECT: (561) 494-1085 |
| FAX: (561) 494-1116 |
| MOBILE: (561) 644-7301 |
| EMAIL: [email protected] |
| WWW.WPB.ORG/ENGINEERING |
| |
| |
| |
| |
| |
| |
| |
| |