Date |
Text |
2012-09-11 10:06:09 | FBC 2010 EXISTING BUILDING CODE |
| FBC 2010 ACCESSIBILITY CODE |
| FBC 2010 PLUMBING REVIEW #1 |
| DENIED: |
| |
| 1. SHEET P-1 & P-2: PLEASE SHOW THAT THE MOP SINK IS |
| INSTALLED ON THE GREASE SYSTEM. |
| P 1003.3.1 ...GREASE INTERCEPTORS AND AUTOMATIC GREASE |
| REMOVAL DEVICES SHALL RECEIVE WASTE ONLY FROM FIXTURES |
| AND EQUIPMENT THAT ALLOW FATS, OILS OR GREASE TO BE |
| DISCHARGED. |
| |
| 2. SHEET P-1 & P-2: A VENT WILL BE REQUIRED SOMEWHERE |
| ON THE GREASE LINE. P 912.2.2 |
| |
| 3. THE EXISTING RESTROOMS DO NOT APPEAR TO MEET THE |
| REQUIREMENTS OF THE 2010 ACCESSIBILITY CODE 604.3.1 & |
| 604.3.2 (5' SIDE CLEARANCE FOR THE WATER CLOSET WITH NO |
| OTHER FIXTURES WITHIN THAT SPACE). PLEASE SEE THE CODE |
| SECTIONS BELOW FOR CHANGE OF OCCUPANCY REQUIREMENTS: |
| |
| EXISTING BUILDING |
| 912.1.4 ACCESSIBILITY. |
| ALL BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY |
| CLASSIFICATION SHALL COMPLY WITH SECTION 912.8. |
| |
| 912.8 ACCESSIBILITY. |
| EXISTING BUILDINGS THAT UNDERGO A CHANGE OF GROUP OR |
| OCCUPANCY CLASSIFICATION SHALL COMPLY WITH THE |
| PROVISIONS OF THE FLORIDA BUILDING CODE, ACCESSIBILITY. |
| |
| ACCESSIBILITY |
| 202.4 ALTERATIONS AFFECTING PRIMARY FUNCTION AREAS. |
| IN ADDITION TO THE REQUIREMENTS OF 202.3, AN ALTERATION |
| THAT AFFECTS OR COULD AFFECT THE USABILITY OF OR ACCESS |
| TO AN AREA CONTAINING A PRIMARY FUNCTION SHALL BE MADE |
| SO AS TO ENSURE THAT, TO THE MAXIMUM EXTENT FEASIBLE, |
| THE PATH OF TRAVEL TO THE ALTERED AREA, INCLUDING THE |
| REST ROOMS, TELEPHONES, AND DRINKING FOUNTAINS SERVING |
| THE ALTERED AREA, ARE READILY ACCESSIBLE TO AND USABLE |
| BY INDIVIDUALS WITH DISABILITIES, UNLESS SUCH |
| ALTERATIONS ARE DISPROPORTIONATE TO THE OVERALL |
| ALTERATIONS IN TERMS OF COST |
| |
| 202.4.1 DISPROPORTIONATE COST. |
| ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE |
| PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| AN INACCESSIBLE DRINKING FOUNTAIN. |
| |
| 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF |
| DISPROPORTIONALITY. |
| WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH |
| OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS |
| DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, |
| THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE |
| EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING |
| DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE |
| ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE |
| ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE |
| FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN |
| ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST |
| ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| ALARMS. |
| |
| REVIEW BY |
| LARRY WAGNER |
| CHIEF PLUMBING INSPECTOR |
| PHONE # 805-6692 |
| EMAIL [email protected] |
| FAX # 805-6676 |
| |
| |