Plan Review Notes For Permit 12080248 |
Permit Number |
12080248 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2012-08-08 17:02:00 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- ACCORDING TO PROPERTY APPRAISAL RECORDS AND AERIAL | | VIEWS THE EXISTING GUEST HOUSE HAS SHINGLES NOT | | CONCRETE TILE. PROVIDE ENGINEERING TO SHOW THAT | | EXISTING STRUCTURE WILL SUPPORT THE ADDITIONAL CONCRETE | | TILE LOAD. SEC. 107.2.1.2 AND SEC. 107.2.1.3 CITY | | AMENDMENTS TO FBC. PROVIDE 2 SIGNED AND SEALED COPIES. | | | | 2- SPECIFY HOW IS THE CONCRETE TILE GOING TO BE | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL. | | IF USING ADHESIVE, THEN PROVIDE PRODUCT APPROVAL LISTED | | ON TILE NOA AS REQUIRED BY DCA RULE 9N-3. PROVIDE 2 | | COPIES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|