2012-08-13 11:39:54 | BUILDING PLAN REVIEW |
| PERMIT: 12071067 |
| ADD: 1950 N CONGRESS # 409 |
| CONT: CILAS CONCRETE |
| TEL: (561)255-3725 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| 1) DISCREPANCIES SHEET A-1 WIND INFORMATION IS |
| INDICATED TO BE DESIGNED TO THE 2010 FBC-B BUT THE |
| BASIC WIND SPEED IS INDICATED AS 140 MPH, 3 SECOND |
| GUST. |
| PLEASE SEE 2010 FBC-B FIGURE 1609A FOR CATEGORY LL |
| BUILDINGS. |
| |
| 2) DISCREPANCIES SHEET A-1 WIND INFORMATION IS |
| INDICATING THIS BUILDING AS A SINGLE FAMILY HOME, IT |
| APPEARS THE UNIT NUMBER BEING 409 THIS IS A R-2 |
| RESIDENCE LOCATED ON THE 4TH FLOOR. ADDITIONAL |
| INFORMATION REQUIRED. 107.2.13 ALSO IF THIS UNIT IS |
| LOCATED ON THE FOURTH FLOOR THERE SHOULD BE A |
| ADJUSTMENT FACTOR FOR HEIGTH. A HEIGHT AND EXPOSURE |
| ADJUSTMENT COEFFICIENT, * SHALL BE DETERMINED FROM 2010 |
| FBC-B TABLE 1609.7.2. ASCE 7-10. |
| |
| 3) DISCREPANCY SHEET A-1 WINDOW TABLE OF POSTIVE & |
| NEGATIVE WINDOW PRESURES IS FOR LAWSON WINDOWS WHEREAS |
| PRODUCT APPROVALS SUBMITTED ARE PGT. PRODUCT APPROVALS |
| SUBMITTED NOT PER PLAN. DISCREPANCY. 107.2.1.3. |
| |
| 3) SHEET A-2 PRESSURES FOR SHEET A-2 ARE INDICATED AS |
| FOR A BUILDING WITH A MEAN ROOF HEIGTH OF 15 FT. , IT |
| IS NOT CERTAIN WITH THE LISTED ABOVE DISCREPANCIES IF |
| THESE PRESSURES ARE V(ULT) OR V(ASD) SEE 2010 FBC-B |
| 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| CHAPTER 6 OF ASCE 7-10. |
| 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| 1609.3 WIND SPEED CONVERSION |
| 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| ACCORDANCE WITH 1609.3.1 & ASCE 7-10 |
| |
| 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. |
| |
| 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| ACCORDANCE WITH 1609.4 & ASCE 7-10 |
| |
| 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| |
| 5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE |
| TABLE 1609.2(2) . |
| |
| A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |