2012-08-01 09:26:48RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- FLAT ROOF RAS 117 CALCULATIONS:
  
 A) ENGINEER TO REVISE THE RAS 117 CALCULATIONS.
 ACCORDING TO SEC. R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL
 THIS BUILDING IS LOCATED ON EXPOSURE "D" NOT "C".
 REVISE CALCULATIONS AS REQUIRED.
  
 ***NOTE: THIS WAS NOTED ON THE FIRST REVIEW COMMENTS TO
 AVOID ANY DELAYS.
  
 B) ENGINEER TO REVISE THE PERIMETER AND CORNER AREA
 MINIMUM DIMENSION. ACCORDING TO FOOTNOTE ON FIGURE
 R301.2(7) THE MINIMUM DIMENSION IS 4'-0" IN ALL CASES
 NOT 3'-0".
  
  