2012-08-28 15:46:17BUILDING PLAN REVIEW
 PERMIT: 12070923
 ADD: 700 S ROSEMARY # 208
 CONT: L & L INTERIOR & REMODELING
 TEL: (561)686-5853
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET 1.7A THE LIFE SAFETY PLAN INDICATES THAT PART
 OF THE NEW A-2 OCCUPANCY IS EXITING THROUGH A PORTION
 OF THE KITCHEN AREA/ STORAGE AREA, PLEASE REVIEW
 2010 FBC-B 1014.2(4).
  
 2) SHEET 1.7A , LIFE SAFETY PLAN THE SAME PATH OF
 TTRAVEL HAS A SECOND ISSUE, WHERE TWO MEANS OF EGRESS
 ARE REQUIRED AND AT LEAST 1/3 RD THE DIAGONAL APART,
 THEY ALSO NEED TO HAVE 2 ACCESSIBLE MEANS OF EGRESS,
 CURRENTLY THE PLANS ONLY INDICATE ONE, PLEASE SEE 2010
 ACCESSIBILITY CODE ADVISORY 105.2.4 ICC/IBC .
  
 3) SHEET 1.6A:
 3A) THE PLANS INDICATE A NEW RAISED PLATFORMED FLOOR
 AREA, THE PLANS DO NOT INDICATE THE DESIGN LIVE LOADS
 IT WAS DESIGNED TOO, 2010 FBC-B TABLE 1607.1(11).
  
 3B) THE PLANS DO NOT PROVIDE THE TOTAL SQUARE FOOT AREA
 OF WHICH THE RAISED PLATFORM FLOOR ENCOMPASSES, APPROX
 2690 SQ FT. THE ISSUE WITH THE NEW PLATFORM AREA IS THE
 NEW WALLS BEING INSTALLED WILL NOW CREATE NEW ROOMS,
 WHEREAS SECTION 410.4 ONLY ALLOWS ONE-THIRD THE THE
 ROOM AREA TO BE RAISED FLOOR.
  
 3C) THE OTHER CONCERNS, THE PLANS DO NOT PROVIDE WHAT
 TYPE OF FLOOR DECKING/ SHEATHING IS TO BE APPLIED TO
 THE STEEL FRAMING, 2010 FBC-B 603.1.1 ALLOWABLE
 COMBUSTIBLES IN TYPE I OR II BUILDINGS.
  
 4) PLEASE PROVIDE SPECIFICATIONS FOR THE HIBACHI
 TABLES, ADDITIONAL FRAMING MAYBE REQUIRED IN THE NEW
 FLOOR FRAMING? ADDITIONAL INFORMATION REQUIRED
 107.2.1.3.
  
 5) SHEET 1.0A NOTE # 6 INDICATES INFILE OF FLOORING BUT
 NO FRAMING DETAILS ARE PROVIDED TO COMPLY WITH 2010
 FBC_B TABLE 1607.1(11).
  
 6) THE COVER SHEET INDICATES THE MINIMUM BUILDING TYPE
 AS A TYPE II SPRINKLERED, THE ORIGINAL BUILDING WAS
 BUILT BEORE THE 2004 FBC, THE BUILDING CLASSIFICATIONS
 CHANGED IN THE 2004 FBC, THE CURRENT BUILDING
 CLASSIFICATION IS NOW A IB PLEASE UPDATE PLANS.
  
 7) THE NEWLY FORMED PORTION OF RESTARAUNT MAY BE A
 CHANGE OF OCCUPANCY AND WOULD REQUIRE PALM BEACH COUNTY
 IMPACT FEE ASSESSMENT. BEFORE A PERMIT TO CONSTRUCT,
 MAY BE ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY. THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED
 BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED
 TO THE PERMIT APPLICATION. PLEASE CALL (561)233-5025
 FOR MORE INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved