Plan Review Notes For Permit 12070774 |
Permit Number |
12070774 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2012-07-31 10:57:00 | RESIDENTIAL (R2) CONCRETE ROOF TILE REPAIRS BUILDING | | REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- ENGINEER TO REVISE CALCULATIONS SUBMITTED. | | A) REVISE THE MOMENT OF RESISTANCE CALCULATIONS FOR | | FIELD AND PERIMETER ZONES. KEEP IN MIND THAT THE DESIGN | | PRESSURES ARE NEGATIVE WHEN RUNNING THE CALCULATIONS. | | SEC. 107.2.1.2 CITY AMENDMENTS TO FBC. | | | | B) CHECK THE HEIGHT OF THE BUILDINGS. ACCORDING TO OUR | | RECORDS BUILDINGS ARE FOUR STORIES HIGH. THEREFORE, | | 30'-0" HEIGHT NEEDS TO BE REVISED. REVISE CALCULATIONS | | AS REQUIRED. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | 2- FOR YOUR INFORMATION: REPAIRS THAT ARE MORE THAN 25% | | OF THE ROOF AREA REQUIRE RE-ROOFING THE ENTIRE ROOF. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|