Plan Review Notes For Permit 12070739 |
Permit Number |
12070739 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2012-08-21 16:08:48 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) SUBMIT ENERGY CALCULATION FORMS FOR THE ENCLOSED | | ENTRY TO SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION | | CHAPTER 4. | | | | 2) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | THE PROJECT PER CITY AMENDMENTS 107.3.4.1. | | | | 3) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | 1/2 ROUND FIXED GLASS WINDOWS AND THE STRUCTURAL WINDOW | | MULLIONS AS REQUIRED BY DCA RULE 9N-3. | | | | 4) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | SIMPSON STRAPS AND CONNECTORS AS REQUIRED BY DCA RULE | | 9N-3. | | | | 5) SPECIFY WHICH ONE OF THE FASTENING METHODS LISTED IN | | THE ROOF TILE PRODUCT APPROVAL WILL BE USED. FBC | | R905.3.7 IF AN ADHESIVE WILL BE USED, SUBMIT TWO COPIES | | OF THE PRODUCT APPROVALS FOR IT AS REQUIRED BY DCA RULE | | 9N-3. | | | | 6) THE DESIGN PRESSURES FOR THE SINGLE OUT-SWING DOOR | | IN THE PRODUCT APPROVAL ARE LOWER THAN THE REQUIRED | | OPENING PRESSURES SPECIFIED ON THE PLANS FOR THE DOOR. | | SUBMIT TWO COPIES OF DOOR PRODUCT APPROVALS WITH DESIGN | | PRESSURES HIGHER THAN THE ONES LISTED ON THE PLANS. FBC | | R301.2.1 | | | | 7) THE PLANS ARE REQUIRED TO BE REVIEWED BY PALM BEACH | | COUNTY TO DETERMINE IF ANY IMPACT FEES WILL BE DUE. THE | | PLANS WITH THE IMPACT REVIEW STAMP AND A COPY OF THE | | PAID RECEIPT WILL BE REQUIRED BEFORE THE PERMIT IS | | ISSUED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|