2012-07-19 14:05:19901 SOUTH OLIVE AVENUE
 PERMIT #12070514
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIRS AND
 PLATFORM ELEVATION CHANGE. HANDRAILS SHALL BE LOCATED
 NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES
 ABOVE THE SURFACE OF THE TREAD, MEASURED VERTICALLY TO
 THE TOP OF THE RAIL FROM THE LEADING EDGE OF THE TREAD.
 HANDRAIL ENDS SHALL BE RETURNED TO THE WALL OR FLOOR OR
 SHALL TERMINATE AT NEWEL POSTS. HANDRAIL CROSS SECTION
 SHALL HAVE A DIAMETER OF NOT LESS THAN 1.25 INCHES AND
 NOT MORE THAN 2 INCHES.
  
 STEPS SHALL HAVE A TREAD DEPTH OF AT LEAST 13-INCHES.
 PROVIDE A CONTRASTING STRIPE ON EACH STEPPING SURFACE
 OF THE LEADING EDGE OR TREAD NOSING TO MAKE THE
 PRESENCE OF AN ELEVATION CHANGE READILY APPARENT TO
 OCCUPANTS.
  