2012-07-11 11:04:28 | BUILDING PLAN REVIEW |
| PERMIT: 12060633 |
| ADD: 1801 S FLAGLER # 1802 |
| CONT: PHILIP JOHNSON, INC. |
| TEL: (561)262-1795 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| BUILDING APPROVED WITH EXCEPTION! |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| |
| PLANS INDICATE NEW FLOORING THROUGH-OUT CONFIRM PER |
| OWNER, PLEASE REVIEW FOR COMPLIANCE: |
| |
| 1) SOUND TRANSMISSION, 2010 FBC-B 1207.3 |
| STRUCTURE-BORNE SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN |
| DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC |
| OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN |
| IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN |
| 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH |
| ASTM E 492. |
| |
| 2) COMBUSTIBLE MATERIAL IN TYPE I & II CONSTRU603.1 |
| ALLOWABLE MATERIALS. COMBUSTIBLE MATERIALS SHALL BE |
| PERMITTED IN BUILDINGS OF TYPE I OR TYPE II |
| CONSTRUCTION IN THE FOLLOWING APPLICATIONS AND IN |
| ACCORDANCE WITH SECTIONS 603.1.1 THROUGH 603.1.3: |
| |
| 2A) TILE FLOORS: (1) INSULATION PLACED BETWEEN TWO |
| LAYERS OF NONCOMBUSTIBLE MATERIALS WITHOUT AN |
| INTERVENING AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME |
| SPREAD INDEX OF NOT MORE THAN 100. |
| |
| |
| JAMES A. WITMER CBO |