2012-06-27 17:05:28****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PROVIDE A STRUCTURAL DETAIL WHICH INCLUDES: WIND
 DESIGN CRITERIA FBC 1603.4.1, ALL CONSTRUCTION AND
 FASTENING DETAILS REQUIRED TO SHOW COMPLIANCE WITH WIND
 DESIGN CRITERIA. FOR INSTANCE, NO INFORMATION REGARDING
 ATTACHMENT OF "STUBS" TO SIGN. 1/4" STUBS SHOWN, NO
 SPECIFICATION FOR MATERIAL OR HOLE SIZE, NO FASTENING
 PATTERN SHOWN; HOW MANY - 2 OR 20? CALCULATIONS MAY BE
 REQUIRED.
  
 2. PROPOSED CONSTRUCTION NOT CLEAR, TWO DIFFERENT SIGNS
 SHOWN; RECTANGULAR AND ROUNDED. FBC107.1.
  
 3. WHEN RESUBMITTING, PROVIDE TWO COMPLETE SETS OF
 PLANS FOR PERMIT ISSUANCE, FBC 107.
  