Date |
Text |
2012-06-15 12:07:05 | PLANNING: ***** FAILED ***** |
| |
| 1. RESPOND TO COMMENTS IN WRITING. |
| |
| 2. PROVIDE DIMENSION AND SQUARE FOOTAGE OF THE BUILDING |
| FACADE WHERE THE SIGN IS PROPOSED TO BE INSTALLED. ONLY |
| INCLUDE THE "LEASABLE AREA" FACADE OF THE BEAUTY SUPPLY |
| BUSINESS (INCLUDE THE TOTAL HEIGHT AND WIDTH OF THE |
| FACADE). |
| |
| 3. THE PROPERTY IS WITHIN THE BROADWAY MIXED USE |
| DISTRICT ("BMUD"), BUILDING TYPE II, THEREFORE THE SIGN |
| STANDARDS ARE AS FOLLOWS: |
| |
| ZLDR, SECTION 94-221(E): |
| |
| (1) THE SIGN AREA SHALL NOT EXCEED 36 INCHES IN HEIGHT |
| BY 60 PERCENT OF THE WIDTH OF EACH SIDE OF THE |
| BUILDING. THIS SIGN AREA SHALL BE LOCATED WITHIN THE |
| FIRST TWO STORIES OF THE BUILDING. IF THE STOREFRONT |
| USES, AWNINGS, THE COPY OR LOGO ON THE VALANCE SHALL |
| NOT EXCEED SIX INCHES IN HEIGHT AND SHALL BE CONSIDERED |
| AS SQUARE FOOTAGE AGAINST THE ALLOWABLE BUILDING |
| SIGNAGE. |
| |
| (2) A SIGN BAND MAY BE LOCATED ON THE REAR OF A |
| BUILDING AND FACING A RESIDENTIAL ZONING DISTRICT SHALL |
| NOT EXCEED ONE AND ONE-HALF (1-1/2) FEET IN VERTICAL |
| DIMENSION BY 30 PERCENT OF THE WIDTH OF THE FACADE |
| WIDTH. THE ILLUMINATION OF THE SIGN SHALL BE DIRECTED |
| ONLY TOWARD THE SIGN FACE. THIS SIGN BAND SHALL BE |
| LOCATED ON THE FIRST FLOOR ONLY. |
| |
| (6) ALL FASTENERS SHALL BE CONCEALED. EXPOSED RACEWAYS, |
| TRANSFORMERS, BALLASTS AND ELECTRICAL WIRING ARE NOT |
| ALLOWED. NO SIGNS WITH VISIBLE BACKS ARE PERMITTED. |
| |
| (7) ALL INSTALLATION COMPONENTS OR HANGING DEVISES SUCH |
| AS, BUT NOT LIMITED TO, FASTENERS, CLIPS, BOLTS, ETC. |
| SHALL BE OF NON-CORROSIVE, STAINLESS STEEL, ALUMINUM, |
| BRASS OR BRONZE; CARBON BEARING STEEL SHALL BE OF |
| NON-FERROUS METAL OF QUALITY MATERIAL AND FINISH. ALL |
| BLACK IRON MATERIALS SHALL BE FINISHED TO WITHSTAND |
| CORROSION. ALL PENETRATIONS OF THE FASCIA SHALL BE |
| NEATLY SEALED IN A WATERTIGHT MANNER USING A SINGLE |
| COMPONENT SILICON SEALANT. ALL SIGNAGE SHALL HAVE AN |
| INDIVIDUAL CIRCUIT AND BE CONTROLLED BY A TIME CLOCK. |
| EXPOSED CONDUIT OR ELECTRICAL WIRING IS PROHIBITED. |
| INTERNALLY ILLUMINATED PANELS ARE PROHIBITED. |
| |
| PLEASE PROVIDE ALL INFORMATION OF WHAT IS ALLOWED VS. |
| PROVIDED FOR THE SIGN SQUARE FOOTAGE ACCORDINGLY. |
| |
| IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. |
| |
| LINDA MIA FRANCO, AICP |
| SENIOR PLANNER |
| PLANNING DIVISION |
| TEL: (561) 822-1443 |
| EMAIL: [email protected] |
| |
2012-06-01 09:10:35 | GIVEN TO LF |