Plan Review Notes For Permit 12050218 |
Permit Number |
12050218 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2012-05-22 12:17:28 | BUILDING PLAN REVIEW | | PERMIT: 12050218 | | ADD: 2465 MERCER AVE # 105 | | CONT: CROSSROADS CONSTRUCTION | | TEL: (561)346-6160 | | | | 2007 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) SHEET A-1: | | | | 1A) THE PROPERTY APPRAISERS SITE INDICATES THIS TO BE A | | COMMERCIAL CONDOMINIUM SITE WITH SEPERATE UNITS, | | PROPERTY LINES AND OWNERSHIP. PLANS WILL NEED TO | | IDENTIFY UNITS AND ASSOCIATED PROPERTY LINES TO COMPLY | | WITH 2010 FBC-B 709.1(6) TENANT SEPERATION WALLS. | | EXCEPTION # 6 FOR TENANT SEPERATION WALLS WILL NOT BE | | APPLICABLE EVEN IF THE ASSUMED 3 SPACES WERE UNDER | | 3,000 SQ FT THERE ARE 3 SEPERATE PCN NUMBERS, THESE ARE | | NOT RENTAL UNITS UNDER ONE OWNERSHIP. | | | | NOTE 5/22/12 WAITING ON E-MAIL FOR LEASE AGREEMENT. JW | | NOTE 5/23/12 RECEIVED LEASE AGREEMENT SPOKE WITH BO | | DOUG WISE ABOUT LEGALLITY. | | NOTE 5/24/12 SPOKE WITH OWNERS, OWNERS ARE TO COMBINE | | UNITS UNDER ONE OWNERSHIP, WILL NEED TO COMPLETE A | | UNITY OF TITLE UNDER OWN PCN. | | | | |
|