Date |
Text |
2012-05-17 11:56:37 | ****CORRECTIONS**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2010 |
| FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL |
| |
| 1 - 3. OK |
| |
| 4. SPECIFY DESIGN PRESSURE REQUIREMENT FOR THE NEW |
| OPENING, FBC R 301.2.1. BOTH INTERIOR AND CORNER ZONE |
| PRESSURES FOR 30 AND 40 SF WERE PROVIDED FOR ONE |
| OPENING, WITH A DIMENSION STATING WHAT THE CORNER |
| DISTANCE IS, BUT NO DIMENSION ON THE DETAIL TO SHOW |
| WHETHER THIS IS ZONE 4 OR 5 AND NO DIMENSION ON THE |
| PLAN FOR THE WINDOW. ENGINEER'S INTENT NOT CLEAR. |
| PLEASE SPECIFY A DESIGN PRESSURE FOR THE ONE OPENING OR |
| CLARIFY SCOPE OF WORK. |
| |
| 2ND REVIEW - NO DIMENSION FROM WINDOW TO CORNER. CANNOT |
| DETERMINE WHICH PRESSURE TO USE. |
| |
| THE WINDOW SIZE WHICH IS HANDWRITTEN IS SMALLER THAN |
| 30SF. DESIGN PRESSURES WERE PROVIDED FOR 30SF AND 40SF, |
| BUT NEITHER NUMBER IS APPLICABLE. PLEASE REVISE. |
| |
| PLEASE INCORPORATE HANDWRITTEN CHANGES (ITEMS ADDRESSED |
| FROM PREVIOUS REVIEW) INTO THE PLAN. |
| |
| 5. IMPACT PROTECTION REQUIRED, FBC R 301.2.1.2. IF |
| SHUTTERS ARE PROPOSED RATHER THAN IMPACT GLASS, PLEASE |
| SUBMIT PRODUCT APPROVALS AND COMPLETE THE SAMPLE |
| INSTALLATION SCHEDULE OR PROVIDE ALL INFORMATION TO |
| SHOW CODE COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC |
| R301, FBC1609. TWO SETS REQUIRED. THIS FORM IS |
| AVAILABLE IN THE LOBBY OR ON THE INTERNET AT |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ |
| INSTALLATION.PDF |
| |
| 2ND REVIEW, REVISE INSTALLATION SCHEDULE AS FOLLOWS: |
| |
| SEE SHEET 1, INSTALLATION > 30' SHUTTER GLASS |
| SEPARATION WAS HIGHLIGHTED, BUT THIS STRUCTURE IS < |
| 30'. |
| |
| REVISE SPAN; THIS SHOULD BE ONE DIMENSION. |
| |
| REVISE VERTICAL/HORIZONTAL, THIS SHOULD BE ONE |
| ORIENTATION. |
| |
| REVIEW CANNOT BE PERFORMED AS NOT ENOUGH INFORMATION |
| PROVIDED. NOTE THAT ANCHOR SPACING/SUBSTRATE ON |
| INSTALLATION SCHEDULE IS NOT CONSISTENT WITH |
| INFORMATION HIGHLIGHTED ON PRODUCT APPROVAL. |
| |
| |
| 6. OK. |
| |
| |