2012-05-04 12:11:08****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. THIS PARCEL IS LOCATED IN EXPOSURE C, FBC
 RESIDENTIAL 301.2.1.4.3.
  
 2. SLIDING WINDOW DETAIL SHOWS A BEVELED BUCK. SEE FBC
 1715.5.4.2, BUCKS SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW FRAME UNLESS OTHERWISE TESTED.
  
 3. PLEASE REVISE CODE REFERENCES; ASCE7 REFERENCE IS
 OUTDATED. PLEASE CORRECT THE FOLLOWING: WIND SPEED (FBC
 R301.2(4), MINIMUM OF 170MPH), EXPOSURE CLASSIFICATION,
 GOVERNING CODE, ASCE7 REFERENCE (FBC R301.2.1.1) AND
 OTHER INFORMATION (SUCH AS DESIGN PRESSURES) AS
 APPLICABLE.
  
 4. SPECIFY DESIGN PRESSURE REQUIREMENT FOR THE NEW
 OPENING, FBC R 301.2.1. BOTH INTERIOR AND CORNER ZONE
 PRESSURES FOR 30 AND 40 SF WERE PROVIDED FOR ONE
 OPENING, WITH A DIMENSION STATING WHAT THE CORNER
 DISTANCE IS, BUT NO DIMENSION ON THE DETAIL TO SHOW
 WHETHER THIS IS ZONE 4 OR 5 AND NO DIMENSION ON THE
 PLAN FOR THE WINDOW. ENGINEER'S INTENT NOT CLEAR.
 PLEASE SPECIFY A DESIGN PRESSURE FOR THE ONE OPENING OR
 CLARIFY SCOPE OF WORK.
  
 5. IMPACT PROTECTION REQUIRED, FBC R 301.2.1.2. IF
 SHUTTERS ARE PROPOSED RATHER THAN IMPACT GLASS, PLEASE
 SUBMIT PRODUCT APPROVALS AND COMPLETE THE SAMPLE
 INSTALLATION SCHEDULE OR PROVIDE ALL INFORMATION TO
 SHOW CODE COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC
 R301, FBC1609. TWO SETS REQUIRED. THIS FORM IS
 AVAILABLE IN THE LOBBY OR ON THE INTERNET AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 6. FBC R 703.6.3, BOND BREAK REQUIRED, PLEASE REVISE
 EXTERIOR WALL FILL IN DETAIL.
  
  