2012-04-26 17:28:26****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. CONTRACTOR HAS NOT PERFORMED THE CONVERSION FROM
 V(ULT) TO V(ASD) CORRECTLY. THE DESIGN PRESSURE IS TO
 MULTIPLIED BY .6 PER FBC RESIDENTIAL 301.2.1.7.
  
 2. THIS PARCEL IS LOCATED IN EXPOSURE D. PLEASE SEE FBC
 RESIDENTIAL 301.2.4.1.3. REVISE DESIGN PRESSURES AND
 DESIGN PRESSURES ACCORDINGLY.
  
 3. TWO COPIES OF THE SCHEDULE FOR INSTALLATION ARE
 REQUIRED. THERE IS A PHOTOCOPY LOCATED IN THE LOBBY FOR
 YOUR CONVENIENCE. THIS FORM MAY BE FILLED OUT IN
 ADVANCE AND IS AVAILABLE ON OUR WEBSITE:
  
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 FAILURE TO PROVIDE TWO COMPLETE SETS OF PERMIT
 DOCUMENTS MAY RESULT IN PERMIT DELAYS.
  
 4. AS THE SHUTTER TO GLASS SEPARATION DOES NOT MEET THE
 MOST STRINGENT REQUIREMENT ON SHEET 11, PLEASE INDICATE
 THE OPTION PROPOSED.
  
  