2012-04-19 14:40:03 | RESIDENTIAL (R3) RENOVATIONS BUILDING REVIEW COMMENTS. |
| 2010 EXISTING BUILDING CODE AND 2010 FLORIDA |
| RESIDENTIAL CODE. |
| |
| 1- ENERGY CALCULATIONS SUBMITTED: |
| A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| INCLUDING OWNER'S NAME, BUILDER'S NAME, ETC. |
| B) REVISE ITEM #1. THIS IS NOT NEW CONSTRUCTION. THIS |
| IS EXISTING HOUSE. |
| C) REVISE ITEM #9(A). NOTES ON DRAWING A-1 SAYS "NEW |
| R19 INSULATION ON EXTERIOR WALLS". REVISE AS REQUIRED. |
| D) HOT WATER SYSTEM IS GAS NOT ELECTRIC. REVISE ITEM |
| #14. |
| E) A/C EQUIPMENT SIZING CALCULATIONS WERE DONE USING |
| WORST CASE SCENARIO. THIS IS NOT ALLOWED. REVISE ITEMS |
| #12 AND # 13 ONCE A/C EQUIPMENT SIZING CALCULATIONS ARE |
| REVISED. |
| F) REVISE TYPE OF DOOR SHOWN ON SHEET 3 OF 5. THERE ARE |
| NOT WOOD DOORS. SEE SHEET A-1. |
| G) THERE IS NOT GARAGE ON THIS BUILDING. REVISE SHEET 3 |
| OF 4. |
| H) MECHANICAL VENTILATION ON SHEET 4 OF 5. IT SAYS |
| THERE IS NOT MECHANICAL VENTILATION. SEE A/C PLAN AND |
| REVISE AS REQUIRED. THERE IS MECHANICAL VENTILATION FOR |
| BATHROOM. |
| |
| 2- ARCHITECT TO SPECIFY CARBON MONOXIDE ALARMS AS |
| REQUIRED BY SEC. R315. |
| |
| 3- ARCHITECT TO SPECIFY THE DESIGN PRESSURES FOR THE |
| EXTERIOR DOORS AND WINDOWS. NOTE: ARCHITECT TO TAKE |
| INTO CONSIDERATION THAT ACCORDING TO SEC. R301.2.1.4.3 |
| THIS BUILDING IS LOCATED ON EXPOSURE "C". |
| |
| 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| DCA RULE 9N-3 FOR: |
| A) ROOF SHINGLES. NOA 11-0411.02 SUBMITTED WAS |
| SUPERSEDED BY MIAMI-DADE. VISIT MIAMI-DADE WEBSITE AND |
| DOWNLOAD CURRENT NOA. |
| B) IN-SWING ENTRY DOOR AS SHOWN ON SHEET A-1. |
| C) DOUBLE FRENCH DOORS AS SHOWN ON SHEET A-1. |
| D) SINGLE HUNG WINDOWS. FLORIDA PRODUCT APPROVAL |
| FL4065-R5 SUBMITTED IS FOR 2007 CODE VERSION. NEED ONE |
| FOR CURRENT 2010 CODE VERSION. |
| E) STORM PANELS. FLORIDA PRODUCT APPROVAL SUBMITTED IS |
| FOR 2007 CODE VERSION. NEED ONE FOR CURRENT 2010 CODE |
| VERSION. AND PROVIDE COMPLETE PRODUCT APPROVAL |
| INCLUDING ALL THE SHUTTERS DRAWINGS. |
| |
| 5- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT |
| SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED |
| BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. |
| |
| 6- PROVIDE COMPLETE INSTALLATION SCHEDULE FOR THE STORM |
| SHUTTERS INSTALLATION. CLEARLY SPECIFY SHUTTERS |
| MOUNTING CONDITION (FOR EXAMPLE WALL MOUNTED, ETC) AND |
| FASTENER TYPE AND SPACING AS REQUIRED BY PRODUCT |
| APPROVAL SUBMITTED TO VERIFY COMPLIANCE WITH THE DESIGN |
| PRESSURES OF SEC. R301.2.1.4.3. |
| |
| 7- CLARIFY IF WINDOWS ARE GOING TO BE REPLACED OR NOT. |
| PLANS ONLY SPECIFY DOORS TO BE REPLACED, BUT WINDOW |
| PRODUCT APPROVAL WAS SUBMITTED FOR REVIEW. |
| |
| 8- WINDOW ON BEDROOM #3 IS REQUIRED TO HAVE SAFETY |
| GLASS. SEC. R308.4(2). |
| |