Plan Review Notes
Plan Review Notes For Permit 12040085
Permit Number 12040085
Review Stop B
Sequence Number 2
Notes
Date Text
2012-07-06 16:58:17BUILDING PLAN REVIEW
 PERMIT:12040085
 ADD: 4312 PINEWOOD
 CONT: ANCHOR GENERAL CONTRACTING
 TEL: (561)386-1266
  
 2010 FLORIDA BUILDING CODE- RESIDENTIAL W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 BUILDING:
 1) CHANGE OF OCCUPANCY FROM GARAGE UTILTY R-3 AN
 EFFICENCY UNIT.
  
 2) 2ND REQUEST, CONTRACTOR TO CHANGE SCOPE OF WORK ON
 THE PERMIT APPLICATION TO INCLUDE " CHANGE OF
 OCCUPANCY".
  
 3) 2ND REQUEST.CHANGE OF OCCUPANCY SCOPE OF WORK HAS
 CHANGED, THE VALUE OF THE PROJECT IS TO LOW PER CITY
 AMENDMENTS 109.3 VALUE NEEDS TO BE ADJUSTED TO REFLECT
 PROPOSED WORK TO BE COMPLETED UNDER THIS PERMIT.
 WPB ADMINISTRATIVE CODE. 109.3 BUILDING PERMIT
 VALUATIONS. IF, IN THE OPINION OF THE BUILDING
 OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL
 BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE
 LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION
 COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.),
 AS PUBLISHED BY INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
 4) COMPLETED.
  
 5) 2ND REQUEST, APPLICABLE CODES, A CHANGE OF OCCUPANCY
 IS NOT A LEVEL 3 ALTERATION PLEASE REVIEW 2010 EXST
 BLDG CODE CHAPTER 9 SECTION 901.3, WHEN A CHANGE OF
 OCCUPANCY OCCURS FOR THE FULL BUILDING THEN SECTION 902
 THROUGH 912 SHALL APPLY.
  
 6) 2ND REQUEST, PROVIDE A WIND LOAD ANALYSIS OF THE
 EXISTING STRUCTURE TO SHOW COMPLIANCE WITH THE
 APPLICABLE WIND LOAD PROVISIONS OF THE FLORIDA BUILDING
 CODE AS REQUIRED BY EXST BLDG CODE 907.2.
  
 7) 2ND REQUEST, SUBMIT A STRUCTURAL DETAIL OF THE
 IN-FILL WALL AT TTHE GARGE OPENING PER CITY AMENDMENT
 107.2.1.3. DISCREPANCY IN PLANS, SHEET A-1 INDICATES
 WOOD INFILL
 PEN SCRATCHED OUT, WHEREAS A2 SECTION B INDICATES CBS
 CONSTRUCTION DETAIL ON A2 INDICATES WOOD INFILL.
  
 8-12) COMPLIED.
  
 13) 2ND REQUEST, WITH THE BATHROOM ONLY BEING 4'-0"
 WIDE IT IS QUESTIONABLE IF THERE WILL BE 21" IN FRONT
 OF THE WATER CLOSET PER FBC-R 307.1.
  
 14-15) COMPLIED.
  
 16) SHOW COMPLIANCE WITH R303.8 FOR REQUIRED HEATING.
  
 17) THE CONTRACTOR ELECTED TO USE NON-IMPACT GLAZING,
 PRODUCT APPROVALS WERE SUBMITTED BUT THE FOLLOWING
 INFORMATION IS STILL UNKNOWN:
 PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.4.
  
 FL BLD CODE 2004 SECTION 106.3.3,
 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING OPENING SIZES, STORY
 HEIGHTS, UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT
 STORM
 BAR REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT
 TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT
 APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT ISSUANCE.
  
 18) COMPLIED.
  
 19) SHOW COMPLIANCE WITH FBC ENERGY CONVERSATION
 101.4.1 & 101.4.5.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  