2012-05-29 15:53:31 | BUILDING PLAN REVIEW |
| PERMIT: 12040044 |
| ADD: 1711 WORTHINGTON BLDG PHASE I BLDG 100 SUITE 108 |
| BUSINESS |
| CONT: ONICX LLC |
| TEL: (813)964-0666 |
| |
| 2010 FLORIDA BUILDING CODE |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| MAY 28/2012 |
| ACTION: DENIED |
| |
| 1) THE CONTRACTOR IS TO COME IN AND CHANGE THE PERMIT |
| APPLICATION UNDER THE HEADING DESCRIPTION OF WORK. THE |
| PERMIT APPLICATION AND PLANS NEED TO USE THE SAME |
| NOMENCLATURE THE PLANS INDICATE THIS PORTION OF WORK AS |
| PHASE I BLDG 100 BUSINESS L/ CHANGE IN OCCUPANCY. |
| |
| 2) SHEET A-0.0 COVER SHEET & INDEX; |
| 2A) COMPLIED. |
| |
| 2B) COMPLIED. |
| |
| 2C) SEMI-COMPLIED. THE HEADING OF CODE INFORMATION |
| FBC-B 803.5 INDICATES, CLASS E FOR EXITS & |
| CORRIDORSCORRECT OCCUPANCY TYPE FOR OFFICES. |
| |
| |
| 2D) PRODUCT APPROVAL ARE LOADED UPSIDE DOWN. |
| THE COVER SHEET ALSO INDICATES THE USE OF YKK YES40F1 |
| WINDOW PRODUCT APPROVALS FL 7606.1 PLEASE NOTE THIS |
| REPORT IS FOR NON- MISSILE RATED GLAZING WHICH WILL |
| REQUIRE PRODUCT TESTING REPORT FOR STORM PANELS. |
| |
| THE OTHER ISSUE WITH THE SUBMITTED FL 7606.1 REPORT |
| ONLY THE COVER SHEETS WERE UPLOADED, THE ACTUAL |
| EVALUATION REPORT WITH PRESSURES WAS NOT INCLUDED NOR |
| WAS THE INSTALATION INSTRUCTIONS THAT TIE TO THE |
| FLORIDA COVER SHEET. |
| |
| PROVIDE STORM PANEL INFORMATION WITH INSTALLATION |
| SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND |
| MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC |
| 1609.1.4. |
| |
| FL BLD CODE 2004 SECTION 106.3.3, |
| 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3. |
| PROCEDURES: 1(B) A COMPLETE INSTALLATION SCHEDULE |
| SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS, |
| UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR |
| REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT |
| TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT |
| APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT |
| ISSUANCE. |
| |
| 2E) THE SECOND PRODUCT APPROVAL THE COVER SHEET LISTED |
| IS FOR EXTERIOR OUTSWING YKK DOOR FL 9967.1 NO REPORT |
| WAS FOUND UNDER THIS PRODUCT NUMBER. |
| |
| 2F) PLEASE CORRECT THE TITLE SHEET FOR THE BUSINESS |
| OFFICES PERMIT BY REMOVING ALL REFREENCES TO THE |
| EDUCATIONAL OCCUPANCY, NOT PART OF THE SCOPE OF WORK |
| UNDER THIS PERMIT. |
| |
| 3) SHEET A-1.0: |
| 3A) PLEASE PROVIDE THE DISTANCE BETWEEN THE TWO |
| BUILDINGS AND PROVIDE COMPLIANCE WITH FBC-B TABLE 602 |
| OR ARE THEY CONSIDERED BUILDINGS ON SAME LOT UNDER |
| FBC-B 503.1.2. |
| |
| 3B) COMPLIED. |
| |
| 4COMPLIED. |
| |
| 5)BUSINESS OCCUPANCY / NOT A CHANGE OF OCCUPANCY , |
| COMPLIED. |
| |
| JAMES A. WITMER CBO |