Plan Review Notes
Plan Review Notes For Permit 12040044
Permit Number 12040044
Review Stop B
Sequence Number 2
Notes
Date Text
2012-05-29 15:53:31BUILDING PLAN REVIEW
 PERMIT: 12040044
 ADD: 1711 WORTHINGTON BLDG PHASE I BLDG 100 SUITE 108
 BUSINESS
 CONT: ONICX LLC
 TEL: (813)964-0666
  
 2010 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 MAY 28/2012
 ACTION: DENIED
  
 1) THE CONTRACTOR IS TO COME IN AND CHANGE THE PERMIT
 APPLICATION UNDER THE HEADING DESCRIPTION OF WORK. THE
 PERMIT APPLICATION AND PLANS NEED TO USE THE SAME
 NOMENCLATURE THE PLANS INDICATE THIS PORTION OF WORK AS
 PHASE I BLDG 100 BUSINESS L/ CHANGE IN OCCUPANCY.
  
 2) SHEET A-0.0 COVER SHEET & INDEX;
 2A) COMPLIED.
  
 2B) COMPLIED.
  
 2C) SEMI-COMPLIED. THE HEADING OF CODE INFORMATION
 FBC-B 803.5 INDICATES, CLASS E FOR EXITS &
 CORRIDORSCORRECT OCCUPANCY TYPE FOR OFFICES.
  
  
 2D) PRODUCT APPROVAL ARE LOADED UPSIDE DOWN.
 THE COVER SHEET ALSO INDICATES THE USE OF YKK YES40F1
 WINDOW PRODUCT APPROVALS FL 7606.1 PLEASE NOTE THIS
 REPORT IS FOR NON- MISSILE RATED GLAZING WHICH WILL
 REQUIRE PRODUCT TESTING REPORT FOR STORM PANELS.
  
 THE OTHER ISSUE WITH THE SUBMITTED FL 7606.1 REPORT
 ONLY THE COVER SHEETS WERE UPLOADED, THE ACTUAL
 EVALUATION REPORT WITH PRESSURES WAS NOT INCLUDED NOR
 WAS THE INSTALATION INSTRUCTIONS THAT TIE TO THE
 FLORIDA COVER SHEET.
  
 PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.4.
  
 FL BLD CODE 2004 SECTION 106.3.3,
 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION SCHEDULE
 SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS,
 UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR
 REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT
 TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT
 APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 2E) THE SECOND PRODUCT APPROVAL THE COVER SHEET LISTED
 IS FOR EXTERIOR OUTSWING YKK DOOR FL 9967.1 NO REPORT
 WAS FOUND UNDER THIS PRODUCT NUMBER.
  
 2F) PLEASE CORRECT THE TITLE SHEET FOR THE BUSINESS
 OFFICES PERMIT BY REMOVING ALL REFREENCES TO THE
 EDUCATIONAL OCCUPANCY, NOT PART OF THE SCOPE OF WORK
 UNDER THIS PERMIT.
  
 3) SHEET A-1.0:
 3A) PLEASE PROVIDE THE DISTANCE BETWEEN THE TWO
 BUILDINGS AND PROVIDE COMPLIANCE WITH FBC-B TABLE 602
 OR ARE THEY CONSIDERED BUILDINGS ON SAME LOT UNDER
 FBC-B 503.1.2.
  
 3B) COMPLIED.
  
 4COMPLIED.
  
 5)BUSINESS OCCUPANCY / NOT A CHANGE OF OCCUPANCY ,
 COMPLIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  