Plan Review Notes For Permit 12030285
Permit Number 12030285
Review Stop B
Sequence Number 2
Notes
Date Text
2012-04-06 09:35:09****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. OK.
  
 2. THE CONTRACTOR'S SIGNATURE IS TO BE NOTARIZED; THIS
 CAN BE DONE AT TIME OF PERMIT PICKUP.
  
 3. PROVIDE PLANS WHICH SHOW PROPOSED WORK AND SCOPE.
  
 2ND REVIEW, NOT ADDRESSED. THE APPLICATION STATES -
 "REPAIR - KITCHEN, BATHROOM, STUCCO REPAIR, WINDOWS,
 DOOR (REMODELING)".
  
 NO INFORMATION PROVIDED REGARDING THE "REMODELING."
 PROVIDE A PLAN WHICH SHOWS SCOPE OF WORK. "SCOPE"
 INCLUDES LOCATION, TYPE OF WORK, AREAS, ETC.
  
 4. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R
 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS
 ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE
 (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM
 /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF)
  
 IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4,
 PROVIDE CALCULATIONS.
  
 DESIGN PRESSURES PROVIDED ARE BASED ON FBC 2010, TOO
 LOW FOR FBC 2007. HOWEVER, BASED ON NOA YOU ARE
 DESIGNING TO +-48PSF, WHICH IS ACCEPTABLE FOR ALL
 OPENINGS.
  
 SHUTTER TO GLASS SEPARATION DOES NOT COMPLY WITH
 REQUIREMENTS ON SHEET 4, REVISE INSTALLATION SCHEDULE.
  
 SPECIFIC ANCHOR TYPE APPEARS TO PROPOSE ELCO PANELMATE,
 BUT IN "TYPE OF ANCHOR SPECIFIED" TAPCON PROPOSED.
 TAPCON IS NOT ONE OF THE OPTIONS FOR WOOD SUBSTRATE.
  
 5. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS,
 SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING
 CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR
 BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING
 CANNOT BE REDUCED BY MORE THAN 5%.
  
 2ND REVIEW, PLAN PROVIDED IS NOT CLEAR AS TO WINDOW
 DIMENSIONS. FOR INSTANCE, NORTH SIDE, 10' IS WRITTEN ON
 ONE SIDE OF THE WINDOW, 4 ON THE OTHER SIDE. WINDOW
 SIZES ARE TO BE SHOWN AS WIDTH X HEIGHT, IN INCHES
 (INDUSTRY STANDARD). IF THERE ARE DOUBLE WINDOWS, THEY
 ARE TO BE SHOWN AND A MULLION USED TO JOIN THE TWO
 WINDOWS. A 10' X 4' WINDOW EXCEEDS THE PRODUCT APPROVAL
 LIMITATION. IF USING MULLIONS, PROVIDE PRODUCT
 APPROVAL.
  
 TWO SETS OF THE FLOOR PLAN REQUIRED.
  
 PLEASE NUMBER OPENINGS TO CORRELATE WITH THE SHUTTER
 INSTALLATION SCHEDULE.
  
 NEW COMMENT:
  
 6. PROVIDE A COST BREAKDOWN, INCLUDING AREAS AND UNIT
 COSTS, MATERIAL AND LABOR. VALUE IS TOO LOW.
  
 THE OFFER TO HAVE ANOTHER PLANS EXAMINER ASSIST YOU IN
 UNDERSTANDING THE COMMENTS REMAINS OPEN. PLEASE FEEL
 FREE TO CONTACT ME IF ASSISTANCE IS NEEDED OR TO
 REQUEST ANOTHER INDIVIDUAL TO COMMUNICATE WITH
 CONTRACTOR.
  
  
  
  
  