2012-04-06 09:35:09 | ****CORRECTIONS**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2007 |
| FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| |
| COMMENTS FROM PREVIOUS LIST: |
| |
| 1. OK. |
| |
| 2. THE CONTRACTOR'S SIGNATURE IS TO BE NOTARIZED; THIS |
| CAN BE DONE AT TIME OF PERMIT PICKUP. |
| |
| 3. PROVIDE PLANS WHICH SHOW PROPOSED WORK AND SCOPE. |
| |
| 2ND REVIEW, NOT ADDRESSED. THE APPLICATION STATES - |
| "REPAIR - KITCHEN, BATHROOM, STUCCO REPAIR, WINDOWS, |
| DOOR (REMODELING)". |
| |
| NO INFORMATION PROVIDED REGARDING THE "REMODELING." |
| PROVIDE A PLAN WHICH SHOWS SCOPE OF WORK. "SCOPE" |
| INCLUDES LOCATION, TYPE OF WORK, AREAS, ETC. |
| |
| 4. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R |
| 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS |
| ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE |
| (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM |
| /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF) |
| |
| IF THIS FALLS UNDER THE 25% EXCEPTION FBC EB 606.4, |
| PROVIDE CALCULATIONS. |
| |
| DESIGN PRESSURES PROVIDED ARE BASED ON FBC 2010, TOO |
| LOW FOR FBC 2007. HOWEVER, BASED ON NOA YOU ARE |
| DESIGNING TO +-48PSF, WHICH IS ACCEPTABLE FOR ALL |
| OPENINGS. |
| |
| SHUTTER TO GLASS SEPARATION DOES NOT COMPLY WITH |
| REQUIREMENTS ON SHEET 4, REVISE INSTALLATION SCHEDULE. |
| |
| SPECIFIC ANCHOR TYPE APPEARS TO PROPOSE ELCO PANELMATE, |
| BUT IN "TYPE OF ANCHOR SPECIFIED" TAPCON PROPOSED. |
| TAPCON IS NOT ONE OF THE OPTIONS FOR WOOD SUBSTRATE. |
| |
| 5. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, |
| SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING |
| CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR |
| BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING |
| CANNOT BE REDUCED BY MORE THAN 5%. |
| |
| 2ND REVIEW, PLAN PROVIDED IS NOT CLEAR AS TO WINDOW |
| DIMENSIONS. FOR INSTANCE, NORTH SIDE, 10' IS WRITTEN ON |
| ONE SIDE OF THE WINDOW, 4 ON THE OTHER SIDE. WINDOW |
| SIZES ARE TO BE SHOWN AS WIDTH X HEIGHT, IN INCHES |
| (INDUSTRY STANDARD). IF THERE ARE DOUBLE WINDOWS, THEY |
| ARE TO BE SHOWN AND A MULLION USED TO JOIN THE TWO |
| WINDOWS. A 10' X 4' WINDOW EXCEEDS THE PRODUCT APPROVAL |
| LIMITATION. IF USING MULLIONS, PROVIDE PRODUCT |
| APPROVAL. |
| |
| TWO SETS OF THE FLOOR PLAN REQUIRED. |
| |
| PLEASE NUMBER OPENINGS TO CORRELATE WITH THE SHUTTER |
| INSTALLATION SCHEDULE. |
| |
| NEW COMMENT: |
| |
| 6. PROVIDE A COST BREAKDOWN, INCLUDING AREAS AND UNIT |
| COSTS, MATERIAL AND LABOR. VALUE IS TOO LOW. |
| |
| THE OFFER TO HAVE ANOTHER PLANS EXAMINER ASSIST YOU IN |
| UNDERSTANDING THE COMMENTS REMAINS OPEN. PLEASE FEEL |
| FREE TO CONTACT ME IF ASSISTANCE IS NEEDED OR TO |
| REQUEST ANOTHER INDIVIDUAL TO COMMUNICATE WITH |
| CONTRACTOR. |
| |
| |
| |
| |
| |