2012-02-27 14:03:50BUILDING PLAN REVIEW
 PERMIT: 12020411
 ADD: 1025 7TH ST.
 CONT: NORTH COUNTY PLUMBING
 TEL: (561)625-9414
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) 2007/09 FBC-B CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 THE PLANS DO NOT PROVIDE DETAILS AS TO LOCATION,
 FIXTURE LOCATION FROM WALLS, CENTER LINE TO CENTER LINE
 OF FIXTURES, DEPTH OF STALLS, SIZE OF DOORS FOR THE
 STALLS NOR THE SIZE AND LOCATION OF THE RESTROOM ENTRY
 DOOR.
  
 2) PLANS ARE NOT DRAWN TO SCALE MAKING IT DIFFICULT TO
 DETERMINE, IF THE DOOR THAT SWINGS INTO THE RESTROOM
 WILL LEAVE ROOM INFRONT OF THE LAVOTORY. PLEASE REVIEW
 FBC-P 405.3.1 FOR REQUIRED CLEARENCE IN FRONT OF THE
 LAVATORIES AND THE RIGHT WATER CLOSET, IT APPEARS THE
 DOOR MAY BUMP INTO THE WATER CLOSET?
  
 3) PLEASE PROVIDE ADDITIONAL INFORMATION FOR WHAT
 APPEARS TO BE STALL PARTITIONS, HOW FAR ARE THEY OFF
 THE FLOOR, AND WHAT WILL THEIR HEIGHT BE? HOW WILL THEY
 BE ANCHORED INTO THE WALL.
  
 4) PLEASE INDICATE COMPLIANCE WITH 2007/09 FBC-B :
 1210.1 FLOORS. IN OTHER THAN DWELLING UNITS, TOILET AND
 BATHING ROOM FLOORS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE THAT EXTENDS UPWARD ONTO THE WALLS
 AT LEAST 6 INCHES (152 MM).
  
 1210.2 WALLS. WALLS WITHIN 2 FEET (610 MM) OF URINALS
 AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM)
 ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS,
 THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE
 THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 5) IT APPEARS THAT THE PLUMBING CONTRACTOR IS TAKING
 THE EXEMPTION UNDER 471.003.(2)(B) IN DESIGNING THEIR
 OWN WORK. A CBCOR CGC WILL NEED TO SIGN ONTO THE PERMIT
 FOR THE BUILDING PORTION OF THE PLANS AND WILL NEED TO
 REVIEW 489.229(1)(C) AS TO WHO MAY DRAW PLANS FOR
 PUBLIC USE.
  
  