2012-02-01 10:08:08****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. DESIGN PRESSURES ARE TOO LOW. THIS IS LOCATED IN
 EXPOSURE C, 140 MPH. DOOR PRODUCT APPROVAL SUBMITTED
 HAS AD DESIGN PRESSURE LIMITATION OF +35.7/-35.7.
 PRODUCT TO BE INSTALLED IS TO HAVE A MINIMUM DESIGN
 PRESSURE OF +39.99/-45.3 FOR A BUILDING WHICH IS 20' IN
 HEIGHT. CONTRACTOR TO PROVIDE BUILDING HEIGHT WHEN
 RESUBMITTING. IF BUILDING HEIGHT EXCEEDS 20', DESIGN
 PRESSURES WILL BE HIGHER. ENGINEERING MAY BE REQUIRED.
 FBC1609.1.
  
  