2012-01-24 10:55:01BUILDING PROVISO:
 GYPSUM BOARD IN SHOWERS
 2007/09 FBC-B 2509.2 BASE FOR TILE. CEMENT,
 FIBER-CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE
 WITH ASTM C 1178, C 1288 OR C 1325 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE
 USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS
 AND WALL AND CEILING PANELS IN SHOWER AREAS.
 WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A
 BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840 AND
 MANUFACTURER RECOMMENDATIONS. REGULAR GYPSUM WALLBOARD
 IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER WALL
 AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH
 GA-216 OR
 ASTM C 840.
  