2012-01-18 13:26:20FBC 2007 PLUMBING REVIEW #1
 DENIED:
  
 THE PLUMBING FIXTURES AS SHOWN ON A-1 APPEAR TO BE TOO
 CLOSE TOGETHER IN THE SPARE BATHROOM. THE WATER CLOSET
 LOOKS TO BE TOO CLOSE TO THE SHOWER IN THE MASTER
 BATHROOM.
 405.3.1 WATER CLOSETS, URINALS, LAVATORIES AND BIDETS.
 A WATER CLOSET, URINAL, LAVATORY OR BIDET SHALL NOT BE
 SET CLOSER THAN 15 INCHES (381 MM) FROM ITS CENTER TO
 ANY SIDE WALL, PARTITION, VANITY OR OTHER OBSTRUCTION,
 OR CLOSER THAN 30 INCHES (762 MM) CENTER-TO-CENTER
 BETWEEN ADJACENT FIXTURES. THERE SHALL BE AT LEAST A
 21-INCH (533 MM) CLEARANCE IN FRONT OF THE WATER
 CLOSET, URINAL, LAVATORY OR BIDET TO ANY WALL, FIXTURE
 OR DOOR. WATER CLOSET COMPARTMENTS SHALL NOT BE LESS
 THAN 30 INCHES (762 MM) WIDE AND 60 INCHES (1524 MM)
 DEEP (SEE FIGURE 405.3.1).
  
 ***NOTE***
 THE PLANS ARE NOT SIGNED AND SEALED.
  