2012-06-11 13:21:44 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW SECOND |
| CHECKLIST. |
| 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| |
| 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| N1100.3 OF CHAPTER 13 FLORIDA RESIDENTIAL CODE. NONE |
| SUBMITED.. |
| |
| 2- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY |
| DCA RULE 9N-3 FOR: |
| A) WINDOWS AS SHOWN ON PLANS. NONE SUBMITED. |
| |
| B) EXTERIOR DOORS AS SHOWN ON PLANS. NONE SUBMITTED. |
| |
| C) FLAT ROOF ASSEMBLY. AND, PLEASE SPECIFY WHICH |
| APPROVED ASSEMBLY IS GOING TO BE INSTALLED. ALSO, |
| PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT |
| PERIMETER AND CORNER AREAS. NOTE: IF THE PRODUCT |
| APPROVAL SUBMITTED REQUIRES SIGNED AND SEALED |
| CALCULATIONS, THEN THOSE CALCULATIONS NEED TO BE SIGNED |
| AND SEALED. NONE SUBMITTED. |
| |
| D) CONCRETE TILE FOR NEW ADDITION. AND, POLYFOAM |
| PRODUCT APPROVAL LISTED ON THE TILE PRODUCT APPROVAL, |
| IF USING ADHESIVE. OTHERWISE, SPECIFY HOW ARE THE TILES |
| GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE |
| DESIGN PRESSURES OF SEC. R301.2.1.4.3. NONE SUBMITTED. |
| |
| E) HURRICANE SHUTTERS IF THE DOORS AND WINDOWS PRODUCT |
| APPROVALS SUBMITTED DON'T HAVE IMPACT GLASS. AND, |
| PROVIDE A COMPLETE SHUTTERS INSTALLATION SCHEDULE. NONE |
| SUBMITTED. |
| |
| F) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS |
| AND DETAILS. NONE SUBMITTED. SUBMITT ONLY THE PRODUCT |
| APPROVAL COVER PAGE AND PAGE SHOWING THE CONNECTOR. |
| THIS APPLIES TO STRUCTURAL CONNECTORS ONLY. |
| |
| 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. |
| |
| 4- THERE ARE NEW PLANS SUBMITTED BY NEW ENGINEER AND |
| REFERENCING THE 2010 FBC. PERMIT APPLICATION WAS |
| SUBMITTED UNDER THE 2007 FBC. PLEASE REVISE PLANS AND |
| REFERENCE THE 2007 FBC FOR THE DESIGN CRITERIA. |
| |
| 5- ROOF FRAMING PLAN SUBMITTED SHOWS NEW RAFTERS |
| CONSTRUCTION, NOT PREFABRICATED ROOF TRUSSES. PROVIDE |
| COMPLETE FRAMING DETAILS SHOWING ATTACHMENT OF RAFTERS |
| TO THE RIDGE AND HIP BEAMS. ATTACHMENT OF THE NEW (2) |
| 2X10 WOOD BEAM AT THE ENDS. SEC. 106.1.1 CITY |
| AMENDMENTS TO FBC. |
| |
| 6- SPECIFY THE CALCULATED DESIGN PRESSURES FOR THE NEW |
| EXTERIOR DOOR AS REQUIRED BY SEC. R301.2.1.4.3 FLORIDA |
| RESIDENTIAL CODE. |
| |
| 7- SPECIFY EGRESS FROM THE EXISTING BEDROOM AS REQUIRED |
| BY SEC. R310. SPECIFY TYPE AND SIZE OF EGRESS WINDOWS |
| SHOWN ON THE CORNER. |
| |
| 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| LOW. UPDATE THE VALUE TO INCLUDE ALL MATERIALS, LABOR, |
| OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS |
| REQUIRED BY SEC. 108.3 CITY AMENDMENTS. |
| |
| 9- PLANS NEED TO SHOW NEW SHOWER DIMENSIONS TO VERIFY |
| COMPLIANCE WITH THE MIN. DIMENSIONS REQUIRED BY SEC. |
| P2708 OF THE 2007 FLORIDA RESIDENTIAL CODE. |
| |
| 10- NEED TO SPECIFY SAFETY GLASS FOR WINDOW LOCATED IN |
| SHOWER AREA IF THE WINDOW HAS NOT IMPACT GLASS. SEC. |
| 308.4(5). |
| |
| 11- REVISE WALL SECTIONS: |
| A) NEED TO SPECIFY 7/8" STUCCO THICKNESS AS REQUIRED BY |
| TABLE R702.1(1). |
| B) NEED TO SPECIFY TWO LAYERS OF WATER RESISTANT |
| BARRIER AS REQUIRED BY SEC. R703.6.3. |
| C) R-30 INSULATION DOESN'T FIT ON 2X6 RAFTERS. |
| COORDINATE WITH THE ENERGY CALCULATIONS. SEC. 106.1.1 |
| CITY AMENDMENTS TO FBC. |
| D) STUCCO CAN'T BE INSTALLED BELOW FINISHED GRADE. SEE |
| SEC. R704.1 AND REVISE AS REQUIRED. |
| E) CLEARLY SHOW LOCATION OF ATTIC VENTS ON THE ROOF |
| FRAMING PLAN TO SHOW COMPLIANCE WITH SEC. R806.1 TO |
| SHOW CROSS VENTILATION. AND, SHOW THE INSULATION |
| CLEARANCE REQUIRED BY SEC. R806.3 SINCE ROOF SLOPE IS |
| VERY LOW. |
| |
| 12- CONNECTOR SCHEDULE ON SHEET A: CLARIFY WHERE ARE |
| THE UPLIFT LOADS OF 985# SPECIFIED FOR THE H8 CONNECTOR |
| TAKEN FROM. PROVIDE ENGINEERED CALCULATIONS. SEC. |
| 106.1.2 CITY AMENDMENTS. |
| |
| 13- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE |
| DUE. BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT. |
| |