Date |
Text |
2011-12-28 13:00:39 | BUILDING PLAN REVIEW |
| PERMIT: 11120195 |
| ADD: 8264 NORTHLAKE BLVD |
| CONT: TO BE DETERMINED |
| TEL: (561)805-6700 SAM DORFMAN |
| |
| 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| 1A) SHEET D1.0 NOTES D1-3 INDICATE THE REUSE OF |
| ANDERSON WOOD WINDOWS AND DOORS. THIS BUILDING (PERMIT |
| # 94013940) WAS BUILT UNDER THE 1991 SBCCI AND THE WIND |
| SPEED WAS 110 MPH FASTEST MILE THAT CONVERTS OVER TO |
| 130 MPH 3 SECOND GUST UNDERTHE 2007/ 09 FBC-B. HOW WILL |
| YOU DEMONSTRATE CODE COMPLIANCE FOR WIND FOR THE |
| ANDERSON WINDOWS AND DOORS? 2007/09 FBC-B 1609 |
| COMPONENTS & CLADDING FOR WIND PRESSURES? |
| |
| 1B) THERE WERE NO PRODUCT APPROVAALS SUBMITTED FOR THE |
| ANDERSON WINDOWS AND DOOR NOR WERE THERE ANY PLANS |
| INDICATING THE TYPE OF FASTENERS TO BE USED IN |
| ANCHORING THE WINDOWS AND DOORS NOR THE SPACING OF |
| ANCHORS. |
| |
| 1C) THE PLANS ALSO INDICATE THERE TO BE STORM SHUTTERS |
| TO BE USED FOR COMPLIANCE WITH THE REQUIREMENT FOR |
| LARGE MISSILE IMPACT COMPLIANCE, PLEASE PROVIDE |
| DOCUMENTATION THAT THE STORM SHUTTERS WILL MEET THE |
| REQUIREMENT FOR LARGE MISSILE AND WIND, 2007/09 FBC-B |
| 1609 COMPONENTS AND CLADDING. |
| |
| 2) THE PLANS DO NOT PROVIDE ANY FASTENING OF FRAMING, |
| SIDING, DECKING, OR ROOF SHEATHING, THE FASTENING |
| TABLES FOUND IN FBC TABLE 2304.9.1 ARE FOR WIND ZONES |
| WITH LESS THAN 100 MPH WINDS. 2007/09 FBC-B 2308.2 (4). |
| |
| 3) SHEET A2.3 INDICATES THE ROOFING PRODUCT APPROVAL # |
| 08-0226.06 POLYGLASS SYSTEM, ONCE THE CONTRACTOR IS |
| AWARDED THE CONTRACT, THE CONTRACTOR WILL NEED TO |
| IDENTIFY WHICH SUB-SYSTEM TO BE INSTALLED, PLEASE NOTE |
| SOME OF THE SUB-SYSTEMS MAY REQUIRE INHANCED FASTENING |
| IN ZONES 2 & 3. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |