Plan Review Notes
Plan Review Notes For Permit 11120076
Permit Number 11120076
Review Stop B
Sequence Number 1
Notes
Date Text
2011-12-05 11:40:55RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PLEASE PROVIDE SIGNED AND SEALED RAS 117
 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND CORNER
 AREAS TO MEET THE DESIGN PRESSURES REQUIRED BY SEC.
 R301.2.1.4.3. GENERAL LIMITATION #7 ON NOA 09-0224.01
 SUBMITTED REQUIRES CALCULATIONS TO BE SIGNED AND
 SEALED. ***NOTE: DESIGN PROFESSIONAL DOING THE
 CALCULATIONS TO TAKE INTO CONSIDERATION THAT THIS
 BUILDING IS LOCATED ON EXPOSURE "C". SEE SEC.
 R301.2.1.4.3.
  
 2- PLEASE CLARIFY IF DOING AN INSULATED ROOF AND A
 NON-INSULATED ROOF. PROVIDE RAS 117 CALCULATIONS FOR
 EACH ONE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712