2013-05-16 09:35:57 | BUILDING PLAN REVIEW |
| PERMIT:11120073 |
| ADD: 700 N CONGRESS |
| CONT: TO BE DETERMINED |
| CONTACT: VIVEK GALAV |
| TEL: (561)644-7416 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| |
| ARCHITECT: REG RICK GONZALEZ |
| TEL: 659-2383 |
| STRUCTURAL ENGINEER: ANDREW MORGAN P. E. |
| TEL: 881-8999 |
| |
| 2ND REVIEW PLANS DATED 06/08/2012 |
| |
| ACTION: DENIED |
| |
| BUILDING PLAN REVIEW |
| PERMIT:11120073 |
| ADD: 700 N CONGRESS |
| CONT: TO BE DETERMINED |
| CONTACT: JEFF HALVERSON |
| TEL: (561)644-7416 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| |
| ARCHITECT: REG RICK GONZALEZ |
| TEL: 659-2383 |
| STRUCTURAL ENGINEER: ANDREW MORGAN P. E. |
| TEL: 881-8999 |
| |
| 3RD REVIEW |
| |
| ACTION: DENIED |
| |
| 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2) ANOTHER ISSUE THAT VINCENT DIDN'T AGREE WITH WAS: |
| SHEET A-4.11 STONE VENEER MISSING THE CONCRETE BEARING |
| EDGE. 2114.2 CONCRETE BEARING LEDGE. BRICK, STONE OR |
| OTHER VENEER SHALL BE SUPPORTED BY A CONCRETE-BEARING |
| LEDGE AT LEAST EQUAL TO THE TOTAL THICKNESS OF THE |
| BRICK, STONE OR OTHER VENEER, WHICH IS POURED |
| INTEGRALLY WITH THE CONCRETE FOUNDATION. NO |
| SUPPLEMENTAL CONCRETE FOUNDATION POURS WHICH WILL |
| CREATE A HIDDEN COLD JOINT SHALL BE USED WITHOUT |
| SUPPLEMENTAL TREATMENT IN THE FOUNDATION UNLESS THERE |
| IS AN APPROVED PHYSICAL BARRIER. AN APPROVED PHYSICAL |
| BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL |
| SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED |
| IN A MORTAR JOINT. IF MASONRY VENEER EXTENDS BELOW |
| GRADE, A TERMITE PROTECTIVE TREATMENT MUST BE APPLIED |
| TO THE CAVITY CREATED BETWEEN THE VENEER AND THE |
| FOUNDATION, IN LIEU OF A PHYSICAL BARRIER. |
| EXCEPTION: VENEER SUPPORTED BY A SHELF, ANGLE OR LINTEL |
| SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH |
| ACI 530/ASCE 5/TMS 402, PROVIDED AT LEAST A 6-INCH (152 |
| MM) CLEAR INSPECTION SPACE OF THE FOUNDATION SIDEWALL |
| EXTERIOR EXIST BETWEEN THE VENEER AND THE TOP OF ANY |
| SOIL, SOD, MULCH OR OTHER ORGANIC LANDSCAPING |
| COMPONENT, DECK, APRON, PORCH, WALK OR ANY OTHER WORK |
| IMMEDIATELY ADJACENT TO OR ADJOINING THE STRUCTURE. |
| |
| |
| 3) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING& FAC |
| RULE 9N-3, PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING |
| REPORTS, MISSING REPORTS ARE AS FOLLOWS: |
| 3A) FIXED GLAZING, STOREFRONT |
| 3B) OPERABLE GLAZING UNITS |
| 3C) MULLIONS, HORIZONTAL AND VERTICAL |
| 3D) GLASS BLOCK |
| 3E) EXTERIOR GLAZED SWING DOORS |
| 3F) EXTERIOR INSULATED METAL SWING DOORS |
| 3G) BI-FOLD APPARATUS BAY DOORS/ WITH TRANSOM |
| 3H) EXTERIOR ROOF WALL ACCESS DOOR/ FRAME (H) |
| 3I) DOUBLE ACCESS PANEL ROOF HATCH, INSULATED -182.6. |
| 3J) WALL LOUVERS |
| 3K) A/C ROOF TOP A/C STANDS |
| 3L) ROOF ASSEMBLIES FLAT ROOF INCLUSIVE OF ROOF TOP |
| INSULATION. |
| 3M) ROOF ASSEMBLIES SLOPED ROOF, METAL ROOF SYSTEMS |
| -266.9 ZONE 3 AND -372.5 ROOF OVERHANGS WITHIN ZONE# 3. |
| 3N) BAHAMA SHUTTERS WITH PRODUCT APPROVAL FOR CLOSED |
| POSITION AND ENGINEERING ANALYSIS FOR SHUTTERS WHEN |
| LEFT IN THE OPEN POSITION IN THE CASE OF A HIGH WIND |
| EVENT. |
| 3O) ROOFTOP EXHAUST FANS |
| |
| VIVEK, VINCENT IS GOING TO LOOK AT SOME TYPE OF ADHERED |
| SYSTEMS THAT WILL GIVE US THE SAME RESULT AS THE |
| CONCRETE LEDGE THAT ACTS AS A TERMITE BARRIER.. |
| |
| 4) WE HAVE THE OTHER ISSUE AS TO WIND SPEED THAT THE |
| ENGINEER OF RECORD IS CREATING A LETTER INDICATING WHY |
| HE HAS DESIGNED THE BUILDING FOR A CAT 5 HURRICANE, IS |
| THIS DESIGN A STRONGER DESIGN THAN THE MINIMUM CODE. |
| DOES HE TAKE A DERATING FACTOR OF 0.77 FOR A BUILDINGS |
| RISK CATEGORY I VERSES A 1.15 REQUIRED FOR A BUILDING |
| RISK CATEGORY IV ??? |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |