Plan Review Notes For Permit 11120036 |
Permit Number |
11120036 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2011-12-09 08:38:28 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- FLAT ROOF: NEW NOA WAS PROVIDED BUT THE REQUESTED | | RAS 117 CALCULATIONS WERE NOT SUBMITTED. PROVIDE RAS | | CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND CORNER | | AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE | | OF NOA SUBMITTED. NEED THE NAIL ENHANCING TO MEET THE | | DESIGN PRESSURES REQUIRED BY SEC. R301.2.1.4.3. WHEN | | DOING THE CALCULATIONS PLEASE TAKE INTO CONSIDERATION | | THAT ACCORDING TO THE 2009 REVISIONS THIS BUILDING IS | | LOCATED IN EXPOSURE "C". SEE SEC. R301.2.1.4.3. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 | | [email protected] |
|