Plan Review Notes For Permit 11110627 |
Permit Number |
11110627 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2012-04-13 10:02:22 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) THE LIVE LOAD FOR THE BALCONY IS REQUIRED TO BE 100 | | PSF BY FBC TABLE 1607.1 (5) & (16). PLEASE REVISE SHEET | | A1 AND VERIFY DECK DESIGN FOR 100 PSF LIVE LOAD. | | | | 2) FBC 1009.4 REQUIRES STAIRWAY LANDINGS TO HAVE A | | MINIMUM DIMENSION MEASURED IN THE DIRECTION OF TRAVEL | | EQUAL TO THE WIDTH OF THE STAIRWAY. PLEASE CORRECT. | | | | 3) SHOW COMPLIANCE WITH FBC 1013.2 HEIGHT. GUARDS SHALL | | FORM A PROTECTIVE BARRIER NOT LESS THAN 42 INCHES (1067 | | MM) HIGH, MEASURED VERTICALLY ABOVE THE LEADING EDGE OF | | THE TREAD, ADJACENT WALKING SURFACE OR ADJACENT | | SEATBOARD. | | NOTE: FBC 1012.2 HEIGHT. HANDRAIL HEIGHT, MEASURED | | ABOVE STAIR TREAD NOSINGS, OR FINISH SURFACE OF RAMP | | SLOPE SHALL BE UNIFORM, NOT LESS THAN 34 INCHES (864 | | MM) AND NOT MORE THAN 38 INCHES (965 MM). EXCEPTION: | | HANDRAILS FOR STAIRS NOT REQUIRED TO BE ACCESSIBLE THAT | | FORM PART OF A GUARDRAIL MAY BE 42 INCHES (1067 MM) | | HIGH. BECAUSE THESE STAIRS ARE NOT REQUIRED TO COMPLY | | WITH ACCESSIBILITY, THE STAIR HANDRAILS CAN BE THE TOP | | OF THE GUARDS AT A HEIGHT OF 42". HOWEVER THE 36" SHOWN | | ON THE PLANS IS NOT ALLOWED. PLEASE CORRECT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|